background image

ATTACH THE WH11 or WH32 TO THE WALL

Attach the WH11 or WH32 at the equipment to a wooden 
surface as shown using the screws and wall anchors supplied. 

Install an R80CJ damper in the duct supplying air to the upstairs 
bedroom area and plug one end of the cable into the connector 
marked IN on the Actuator and the other end into the connector 
marked SLEEPING DAMPER on the Wiring Hub. Install a second 
R80CJ damper in the duct supplying air to the downstairs living 
area and plug one end of the cable into the connector on the 
Actuator marked IN and the other end into the connector on the 
Wiring Hub marked LIVING DAMPER.  Each damper uses 2.4VA 
of power.  

When two or more dampers are required to define the upstairs or 
downstairs areas, the second damper may be plugged into the 
connector marked OUT on the first damper.  LEDS on the damper 
actuator indicate when the damper is fully open (green) or fully 
closed (red).

INSTALL UPSTAIRS & DOWNSTAIRS DAMPERS

Ensure that damper installation does not cause 
obstruction to the damper blade.

WIRING INSTRUCTIONS

Wiring Thermostat to WH11 or WH32 Wiring Hub

Use 5-conductor(1 spare), 18 or 20 gage, thermostat cable to 
wire the WH11 or WH32 Wiring Hub to a C365C42 or 
C365C42WF Communicating Thermostat.

C365

Terminal

5V

GND

SA

SB

Wire Color

Red

White

Blue

Yellow

Wiring Hub

Terminal

5V

GND

SA

SB

Function

24VAC Power

Common

Signal A
Signal B

!

Green LED

Red LED

4-5/16 inches

+5V

GND

SB

WIRING HUB

SA

Thermostat Model C365C42 or C365C42WF

Existing thermostat cable
in replacement installations.

Wiring Diagram

C365C42

Wiring Hub Model WH11 or WH32 

Warning - Only use plug and play cable provided 
with the A80MJ actuator. Additional cables can be 
ordered through eControls, Model #PIC25 (25 ft.).

!

R

C

W/B

O

Y

G

W2/E

Y2

SLP

SLP

SENSORS

TSTAT

HVAC

ODT

ODT

GND

+5V

SA

SB

LIVING SLEEP
SPACE SPACE

DMPR

DMPR

INSTALLER

Warning!

!

Turn the power to the HVAC equipment off before wiring.

Summary of Contents for WH11

Page 1: ...Up to 6 dampers can be daisy chained to define the Upstairs Sleeping or Downstairs Living area One or two wired sensors can be used in the upstairs sleeping space For single sensor installations use...

Page 2: ...ayed on the thermostat User Airflow Control Manual Airflow Control can be enabled in the User Options Go to Menu Option 2 and turn off automatic airflow control Read entire manual before installing pr...

Page 3: ...ndicate when the damper is fully open green or fully closed red INSTALL UPSTAIRS DOWNSTAIRS DAMPERS Ensure that damper installation does not cause obstruction to the damper blade WIRING INSTRUCTIONS W...

Page 4: ...are provided HAND TIGHTEN Printed circuit board Brass washer Model TS510W Remote Temperature Sensor Model TS520W Remote Temperature Sensor Model TS520W Remote Temperature Sensor Wiring Hub WH11 or WH3...

Page 5: ...nstallation install the sensor on an interior wall about 4 feet above the floor and in a location that best senses the upstairs sleeping space temperature For a dual sensor installation install the se...

Page 6: ...needs to be documented for future reference Use the removable labels included with the thermostat to identify the sensors as 1 or 2 Place the labels on the front of the thermostat over the battery cov...

Page 7: ...m Hallway See Note 1 Required when using dual fuel heat pumps Sensor installed in Master Bedroom See Note 2 See Note 1 See Note 2 Use TS510W sensor for single sensor installations Use two TS520W senso...

Page 8: ...Link ELR1 Plugin Radio Module 4 2 IN OUT IN OUT P P P P GND R ODT R GND 5V C ODT C 5V SA W B W B SA SB 0 0 Y Y G G W2 E W2 E Y2 Y2 SB Model TS3 Temperature Sensor 10K 77F Made in USA Wiring Diagram In...

Reviews: