background image

CAUTIONS

Use cautions when mounting components to surfaces 
that may have concealed wiring beneath the surface.

!

INSTALLATION

Before installing the Comfort365 system, turn off
all power to your HVAC system.

Read and follow all instructions carefully.

Follow all local electrical codes during installation. All
wiring must conform to local and national electrical 
codes.

i

ATTENTION INSTALLER

Nighttime Airflow Control is defaulted to ON. If 
bedrooms are located downstairs, consider turning this
option Off using the User Options if bedrooms are not 
on the same trunk.

Airflow Control is defaulted to On and controlled by 
Options 50 thru 53.

Install and wire components to the wiring hub. 

Airflow Control Off Option 50 turns off Airflow Control
and the thermostat operates as a typical thermostat.
The thermostat controls the system, dampers fully open, 
nighttime airflow control is disabled and airflow is no
longer displayed on the thermostat.

User Airflow Control (Manual Airflow Control) can be
enabled in the User Options. Go to Menu Option #2 
and turn off automatic airflow control. 

Read entire manual before installing products.

When servicing Comfort365 system or accessing 
products, turn off all power to these items.

Place the thermostat on the subbase. Do not install 
batteries. (See C365C42 or C365C42WF manual).

Turn power to the HVAC equipment On.

Check for Start Up Messages/Errors.

Set equipment options 1-6 if different than factory 
default settings. (see C365C42 or C365C42WF 
manual).

1)

3)

If wireless sensors are used, install the ELR1 plug in
radio module in the wiring hub and set the sensor 
number and home number as necessary.

2)

4)

5)

6)

Test the installation by initiating a heating call, cooling 
call and fan call.

7)

Install batteries and set the time and day (see 
C365C42 or C365C42WF manual).

8)

i

Homes with plaster walls with steel lathe may 
experience wireless communication interference
when using wireless sensors. Wired sensors are
recommended under those conditions.

INSTALLER

Refer to C365C42 or C365C42WF manuals for accessing:

Summary of Contents for WH11

Page 1: ...Up to 6 dampers can be daisy chained to define the Upstairs Sleeping or Downstairs Living area One or two wired sensors can be used in the upstairs sleeping space For single sensor installations use...

Page 2: ...ayed on the thermostat User Airflow Control Manual Airflow Control can be enabled in the User Options Go to Menu Option 2 and turn off automatic airflow control Read entire manual before installing pr...

Page 3: ...ndicate when the damper is fully open green or fully closed red INSTALL UPSTAIRS DOWNSTAIRS DAMPERS Ensure that damper installation does not cause obstruction to the damper blade WIRING INSTRUCTIONS W...

Page 4: ...are provided HAND TIGHTEN Printed circuit board Brass washer Model TS510W Remote Temperature Sensor Model TS520W Remote Temperature Sensor Model TS520W Remote Temperature Sensor Wiring Hub WH11 or WH3...

Page 5: ...nstallation install the sensor on an interior wall about 4 feet above the floor and in a location that best senses the upstairs sleeping space temperature For a dual sensor installation install the se...

Page 6: ...needs to be documented for future reference Use the removable labels included with the thermostat to identify the sensors as 1 or 2 Place the labels on the front of the thermostat over the battery cov...

Page 7: ...m Hallway See Note 1 Required when using dual fuel heat pumps Sensor installed in Master Bedroom See Note 2 See Note 1 See Note 2 Use TS510W sensor for single sensor installations Use two TS520W senso...

Page 8: ...Link ELR1 Plugin Radio Module 4 2 IN OUT IN OUT P P P P GND R ODT R GND 5V C ODT C 5V SA W B W B SA SB 0 0 Y Y G G W2 E W2 E Y2 Y2 SB Model TS3 Temperature Sensor 10K 77F Made in USA Wiring Diagram In...

Reviews: