background image

R

C

W/B

O

Y

G

W2/E

Y2

SLP

SLP

SENSORS

TSTAT

HVAC

ODT

ODT

GND

+5V

SA

SB

LIVING SLEEP
SPACE SPACE

DMPR

DMPR

Description

Compatible Equipment, WH11

Power

Power Indicator

Damper Actuators

Wired Temperature Sensor

Wireless Temperature Sensor

The Wiring Hub is installed at the equipment.  It is connected to 
the C365C42 or C365C42WF thermostat using the existing or 
new 4-wire thermostat cable that normally connects the 
thermostat to the equipment.  The equipment is wired directly to 
the Wiring Hub.  The upstairs sensor can be either a wired or 
wireless sensor.  Wireless sensors use the ELR1 Radio Module 
that plugs into the Wiring Hub.  An outdoor temperature sensor 
can also be used to control fossil fuel heating in a dual fuel heat 
pump (WH32 only).

Gas/Electric equipment with 1 heat/ 1 Cool.

Powered by 24VAC from the equipment R and C terminals

LED indicator.

Uses A80MJ Plug&Play damper Actuators.  Up to 6 dampers 
can be daisy chained to define the Upstairs Sleeping or 
Downstairs Living area.

One or two wired sensors can be used in the upstairs sleeping 
space. For single sensor installations use TS510W sensor.  For 
two-sensor installations, use two TS520W sensors.

One or two battery powered, wireless sensors can be used.  The 
ELR1 Radio Module must be installed in the Wiring Hub when 
wireless sensors are used.  Use the TS5WL sensor for 1 or 2-
sensor installations.

Installer Manual

Wiring Hub, Model WH11 and WH32

365

Comfort

Ver 2.40 Sep 2018

Screw attaches cover to base.

Cover.

Optional eLink Radio Module plugs into connectors.

24VAC Power Indicator.

Terminals for wiring

to HVAC equipment.

Terminals for Upstairs Remote 

wired temperature sensor.

Terminals for optional outdoor

temperature sensor.

Terminals for wiring to
Comfort365 Thermostat.

Connector for Downstairs Living Space 
Plug&Play Modulating Damper.

Connector for Upstairs Sleeping Space 
Plug&Play Modulating Damper.

Compatible Equipment, WH32

Gas/Electric equipment, conventional and dual fuel heat pump 
equipment with 3 heat/ 2 Cool.

Summary of Contents for WH11

Page 1: ...Up to 6 dampers can be daisy chained to define the Upstairs Sleeping or Downstairs Living area One or two wired sensors can be used in the upstairs sleeping space For single sensor installations use...

Page 2: ...ayed on the thermostat User Airflow Control Manual Airflow Control can be enabled in the User Options Go to Menu Option 2 and turn off automatic airflow control Read entire manual before installing pr...

Page 3: ...ndicate when the damper is fully open green or fully closed red INSTALL UPSTAIRS DOWNSTAIRS DAMPERS Ensure that damper installation does not cause obstruction to the damper blade WIRING INSTRUCTIONS W...

Page 4: ...are provided HAND TIGHTEN Printed circuit board Brass washer Model TS510W Remote Temperature Sensor Model TS520W Remote Temperature Sensor Model TS520W Remote Temperature Sensor Wiring Hub WH11 or WH3...

Page 5: ...nstallation install the sensor on an interior wall about 4 feet above the floor and in a location that best senses the upstairs sleeping space temperature For a dual sensor installation install the se...

Page 6: ...needs to be documented for future reference Use the removable labels included with the thermostat to identify the sensors as 1 or 2 Place the labels on the front of the thermostat over the battery cov...

Page 7: ...m Hallway See Note 1 Required when using dual fuel heat pumps Sensor installed in Master Bedroom See Note 2 See Note 1 See Note 2 Use TS510W sensor for single sensor installations Use two TS520W senso...

Page 8: ...Link ELR1 Plugin Radio Module 4 2 IN OUT IN OUT P P P P GND R ODT R GND 5V C ODT C 5V SA W B W B SA SB 0 0 Y Y G G W2 E W2 E Y2 Y2 SB Model TS3 Temperature Sensor 10K 77F Made in USA Wiring Diagram In...