www.desatech.com
111487-01G
9
IMPORTANT:
Vent-free heaters add moisture
to the air. Although this is beneficial, installing
heater in rooms without enough ventilation
air may cause mildew to form from too much
moisture. See
Air for Combustion and Ventila-
tion
, page 5.
CHECK GAS TYPE
Use the correct gas type (natural or propane/
LP) for your unit. If your stove heater gas type
is different from your house gas type, do not
install heater. Call dealer where you bought
heater for proper type heater.
WARNING: This appliance is
equipped for either natural gas
or propane/LP gas but not both.
Gas type is indicated on the rat-
ing plate. Field conversion is not
permitted.
CLEARANCES TO COMBUSTIBLES
(Vent-Free Operation Only)
WARNING: Maintain the
minimum clearances. If you can,
provide greater clearances from
floor, ceiling and adjoining side
and back walls.
Carefully follow the instructions below. This
stove is a freestanding unit designed to set
directly on the floor. DO NOT place stove
directly on carpeting, vinyl tile or any combus-
tible material other than wood. The stove must
be set on a metal or wood panel extending
the full width and depth of the stove for these
floor coverings. Important: You must maintain
minimum wall and ceiling clearances during
installation. The minimum clearances are
shown in Figure 5. Measure from outermost
point of stove top.
Minimum Wall and Ceiling Clearances
(see Figure 5)
A. Clearances from outermost point of stove
top to any combustible side wall should
not be less than 12".
B. Clearances from outermost point of stove
top to any combustible back wall should
not be less than 6" (includes corner instal-
lations).
INSTALLATION
Continued
C. Clearances from the stove top to the ceil-
ing should not be less than 48".
Figure 5 - Minimum Clearance to Walls
and Ceiling (Stove May Vary Depending
on Model)
Front View
Top View
Side View
12"
Minimum
12"
Minimum
48"
Minimum
Ceiling
Side Wall
Side Wall
Back Wall
Side Wall
Side Wall
12 "
Minimum
12 "
Minimum
6 "
Minimum
6"
Minimum
48"
Minimum
Ceiling
Floor
Back Wall
Corner
Wall
Wall
6 "
Minimum
6 "
Minimum
Front of Stove Unit
Front of Stove
Unit
Front of
Stove Unit