Comfortflame.US.com
900577-00_NC
15
TROUBLESHOOTING
WARNING: Turn off appliance and let cool before servicing. Only a qualified service person should service
and repair appliance.
CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
Note:
All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Igniter electrode not connected to Igniter
cable
2. Igniter cable pinched or wet
3. Broken Igniter cable
4. Bad piezo Igniter
5. Igniter electrode broken
6. Igniter electrode positioned wrong
1. Gas supply turned off or equipment shutoff
valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in
PILOT position
4. Air in gas lines when installed
5. ODS/pilot is clogged
6. Gas regulator setting is not correct
7. Depleted gas supply (propane/LP only)
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Equipment shutoff valve not fully open
4. Pilot flame not touching thermocouple,
which allows thermocouple to cool, caus-
ing pilot flame to go out. This problem
could be caused by one or both of the
following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot
5. Thermocouple connection loose at con-
trol valve
6. Thermocouple damaged
7. Control valve damaged
REMEDY
1. Reconnect Igniter cable
2. Free Igniter cable if pinched by any metal
or tubing. Keep Igniter cable dry
3. Replace Igniter cable
4. Replace piezo Igniter
5. Replace pilot assembly
6. Replace pilot assembly
1. Turn on gas supply or open equipment
shutoff valve
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT
position
4. Continue holding down control knob.
Repeat igniting operation until air is
removed
5. Clean ODS/pilot (see Cleaning and Main-
tenance, page 14) or replace ODS/pilot
assembly
6. Replace gas control
7. Contact local propane/LP gas company
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob
pressed in 30 seconds
3. Fully open equipment shutoff valve
4.
A) Contact local propane/LP or natural gas
company
B) Clean ODS/pilot (see Cleaning and
Maintenance, page 14) or replace ODS/
pilot assembly
5. Hand tighten until snug, then tighten 1/4
turn more
6. Replace pilot assembly
7. Replace control valve
OBSERVED PROBLEM
When Igniter button is pressed, there is no
spark at ODS/pilot
When Igniter button is pressed, there is
spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when
control knob is released