Comfort Flame NCBurnerZMN Installation And Operation Instructions Manual Download Page 11

Comfortflame.US.com

900577-00_NC

11

INSTALLATION 

Continued

PRESSURE TESTING APPLIANCE GAS CONNECTIONS

1.  Open equipment shutoff valve (see Figure 11, page 10).
2.  Open main gas valve located on or near gas meter for natural gas 

or open propane/LP supply tank valve.

3.  Make sure control knob of appliance is in the OFF position.
4.  Check all joints from equipment shutoff valve to control valve (see 

Figure 12 or 13). Apply a noncorrosive leak detection fluid to gas 

joints. Bubbles forming show a leak.

5.  Correct all leaks at once.
6.  Light appliance (see Operation, page 12). Check all other internal 

joints for leaks.

7.  Turn off appliance (see To Turn Off Gas to Appliance, page 13).

Figure 12 - Checking Gas Joints (Stove Model Shown)

Control Valve Location

Propane/LP 

Supply Tank

Equipment Shutoff Valve

Figure 13 - Checking Gas Joints Stove Model Shown)

Gas Meter

Equipment 

Shutoff Valve

Control Valve Location

INSTALLING ROD AND SCREEN

1.  Insert rod through small rings located at top of screen (see Figure 

14).

2.  From back of stove, insert rod into hole located inside right front 

of stove as shown in Figure 15.

3.  Slip left side of rod down into slot on inside left front of stove 

(see Figure 15).

Figure 14 - Assembling Rod and Screen

Rod

Rings

Figure 15 - Installing Screen Into Stove (View From Back of 

Stove)

Slot on Inside 

Left Front of 

Stove

Hole on Inside 

Right Front of 

Stove

Rod with 

Screen 

Assembled

Summary of Contents for NCBurnerZMN

Page 1: ...iance It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 5 of...

Page 2: ...g DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poi soning resemble the flu with headaches dizziness or nausea If you have these signs the...

Page 3: ...ood burning fireplace Use only model NCBurnerZMN P series vent free gas log appliance for Newcastle cast iron stove models 6 Do not add extra logs or ornaments such as pine cones vermiculite or rock w...

Page 4: ...allation in the US state of Massachusetts if the following additional requirements are met Un vented Room Heaters shall be installed in accordance with 527 CMR 30 Installation and repair must be done...

Page 5: ...al fresh air See Ventilation Air From Outdoors page 6 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow For Fireplace Location Confined and Unconfined Sp...

Page 6: ...orapplicablelocalcodes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must prov...

Page 7: ...ustion and Ventilation page 5 CHECK GAS TYPE Use only the correct type of gas natural or propane LP If your gas supply is not the correct gas type do not install appliance Call dealer where you purcha...

Page 8: ...r failure to use only parts specifically approved with this appliance may result in property damage or personal injury 1 Remove log from carton 2 Remove all protective packaging applied to log for shi...

Page 9: ...could occur Install external regulator with the vent pointing down as shown in Figure 9 Pointing the vent down protects it from freezing rain or sleet CAUTION Use only new black iron or steel pipe Int...

Page 10: ...1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage appliance...

Page 11: ...nts for leaks 7 Turn off appliance see To Turn Off Gas to Appliance page 13 Figure 12 Checking Gas Joints Stove Model Shown Control Valve Location Propane LP Supply Tank Equipment Shutoff Valve Figure...

Page 12: ...ear the floor If you smell gas STOP Follow B in the safety information If you don t smell gas go to the next step 6 Press in and turn control knob counterclockwise to the PILOT position Press in contr...

Page 13: ...and burner flame patterns often PILOT FLAME PATTERN Figure 19 shows a correct pilot flame pattern Figure 20 shows an incorrect pilot flame pattern The incorrect pilot flame is not heating the thermoco...

Page 14: ...the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Your local computer store hardware store or home center...

Page 15: ...gas pressure B Dirty or partially clogged ODS pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect Igniter cable 2 Free Igniter cab...

Page 16: ...an burner see Cleaning and Mainte nance page 14 or replace burner orifice 1 Clean burner see Cleaning and Mainte nance page 14 or replace burner orifice 2 Replace damaged burner 3 Replace gas control...

Page 17: ...essure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at...

Page 18: ...plier TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting Please contact your IHP dealer for any questions or concerns When contacting your dealer please h...

Page 19: ...urned on and off by using a hand held remote control ON OFF F1077 MRC Standard On Off Remote Control Kit RECEIVER AND ON OFF TOUCH SCREEN REMOTE CONTROL KIT For all Remote Ready Models Allows the burn...

Page 20: ...mfortflame US com 900577 00_NC 20 PARTS MODELS NCBURNERZMN AND NCBURNERZMP O F F P I L O T O N H I L O H I L O O F F P I L O T O N 17 17 18 19 24 15 14 16 13 12 12 11 22 23 20 10 9 21 4 8 5 3 2 21 7 6...

Page 21: ...3 1 11 J3808 LOWER BRACKET 1 12 J1958 SCREW HWH AB 8 18 X 38 7 13 PAINTED BASE ASSEMBLY 1 14 J3569 CABLE IGNITER 1 15 J3746 KIT IGNITER SERVICE 1 16 J3821 PLATE SWITCH 1 17 J3574 SCREW PPH AB 10 16 X...

Page 22: ...________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __...

Page 23: ...el will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the i...

Page 24: ...r name P900577 00 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products...

Reviews: