Service Manual -
DVC 09/12/18/24 SF Series
33
38
Remark:
Use a multimeter to test the DC voltage
between
terminal L
2 and
terminal
3
(
S
)
of
outdoor unit. The red pin of multimeter
connects with 2 port while the black pin is
for
terminal 3(
S
)
.
When AC is normal running, the voltage
will move alternately between -25V to
25V.
If the outdoor unit has malfunction, the
voltage will move alternately with positive
value.
I
f the indoor unit has malfunction, the
voltage will be a
steady
value.
Remark:
Use a multimeter to test the resistance
of the reactor which does not connect
with capacitor.
The normal value should be around
zero ohm. Otherwise, the reactor
is
malfunction
ing
.