5.3 Pipe length and the elevation
The pipe length and refrigerant amount:
Model
Pipe size
Standard
L
ength
(m)
Max.
Elevation
B (m)
Max.
Length
A (m)
Additional
R
efrigerant
(g/m)
Gas
Liquid
DVC09SF-0
3/8’’
(Ф9.52)
1/4’’
(Ф6.35)
7.5
10
25
15
DVC12SF-0
DVC18SF-1
DVC24SF-1
1/2’’
(Ф12.7)
1/4’’
(Ф6.35)
7.5
10
25
15
7.5
10
25
15
5/8"
(Ф15.9)
3/8’’
(Ф9.52)
7.5
20
30
30
Caution:
The capacity test is based on the standard length and the maximum permissive length is based on the system
reliability.
25 ft
32 ft
82 ft
.16 oz/ft
25 ft
32 ft
82 ft
25 ft
64 ft
98 ft
1/2’’
(Ф12.7)
1/4’’
(Ф6.35)
.16 oz/ft
.16 oz/ft
.323 oz/ft
25 ft
64 ft
98 ft
Summary of Contents for A-DVC09SF-0
Page 8: ...Service Manual DVC 09 12 18 24 SF Series 8 6 For B DVC09SF 0 For B DVC12SF 0 For B DVC18SF 1 ...
Page 9: ...Service Manual DVC 09 12 18 24 SF Series 9 7 For B DVC24SF 1 ...
Page 13: ...Service Manual DVC 09 12 18 24 SF Series 13 For A DVC24SF 1 ...
Page 14: ...Service Manual DVC 09 12 18 24 SF Series 14 4 Refrigerant Cycle Diagram ...
Page 42: ...Service Manual DVC 09 12 18 24 SF Series 42 47 P W N U ...
Page 43: ...Service Manual DVC 09 12 18 24 SF Series 43 48 N V N W ...
Page 55: ...Service Manual DVC 09 12 18 24 SF Series 55 This page intentionally left blank ...