A continuous recording with a preset interval is ON and running.
The recording is ON in the device and it is running at present.
This kind of display is utilized, when the record activity is dependent
on the alarm or the external input condition.
The recording is ON in the device but it is not running at present.
For instance, the rrecording is ON during an alarm only, and there
is no alarm just now. Or, a recording is ON that is controlled by
an external input which not active at the moment.
The LOG symbol is not displayed: The recording is OFF in the device.
The recording is not allowed in any channel in the device’s
configuration.
Meaning of the values displayed
- this item specifies the meaning
of the measured values displayed in the two main rows. Beside the currently
measured values the device will also evaluate the minimum and maximum
values from their last resetting by the user.
If the device is OFF and has not
been running for some time, then, after it is turning ON, the value of Min /
Max is then set to the values before switching OFF.
It can be preset
in the device configuration, whether and in what manner these Min/Max
values will be displayed by the device. Remember that the Min/Max
in question are different from those being recorded.
Neither MIN nor MAX is displayed. You can see values that
have been currently measured.
In both display rows you can see the minimum values measured
since their last resetting by the user.
In both display rows you can see the maximum values measured
since their last resetting by the user.
Alarm condition
- this item provides instant information that at least one
of the alarms which have been preset is active. Alarms can be generated by
exceeding the limits that have been preset in individual channels. Moreover,
they can notify of a device failure. In the device configuration you can preset
which conditions should be considered as alarm generating. By means
of the upper key you can easily browse through the values measured in all
device channels (if enabled in device configuration). In the case
that the value is preceded by a bell-like icon, the preset limits (alarms) have
been exceeded in this channel.
GSM modem active
- this symbol indicates that a power supply has been
connected to the GSM modem because of some online work.
Summary of Contents for U0110M
Page 5: ...IE LGR UxxxxM 22 5 Datalogger UxxxxM U0141M model...
Page 60: ...60 IE LGR UxxxxM 22 Dimensions U0110M U8410M U0121M...
Page 61: ...IE LGR UxxxxM 22 61 U0141M U3120M U4440M...
Page 62: ...62 IE LGR UxxxxM 22 U3121M U3631M...
Page 63: ...IE LGR UxxxxM 22 63 U0141TM U0843M U5841M U6841M U7841M...