• Perform the checks required by routine maintenance.
• The equipment must be protected against freezing: if it is not possible to protect this way, before starting
it, take it to a warm environment for long enough to melt any ice inside. Failure to do so could cause
serious damage to the equipment.
• If the equipment is used above 1000 m/3281 ft of height, contact a SKILLED TECHNICIAN for a check
and a possible combustion adjustment.
• The use of agricultural, heating or dirt diesel fuel causes excessive deposits onto the burner, thus impairing
its good operation.
• After use, before performing the “STOP” procedure, run the equipment with the burner off for a few
minutes so as to cool down the delivery circuit.
STANDARD EQUIPMENT
Make sure that the product purchased consists of the following elements:
• mobile boiler;
• high-pressure connection hose to the combined high-pressure cleaner;
• instruction book;
• rotating coupling (27) for connecting to the high-pressure cleaner M22x1,5 (HOTBOX 25/350 only);
• water outlet fitting M22x1,5 (29) (HOTBOX 25/350 only);
• declaration of conformity;
• warranty certificate;
• booklet giving the service centres.
If there are any problems, contact the Manufacturer or an authorized service centre.
INSTALLATION - FITTING ACCESSORIES
• Using a 22 mm/0.86 in hexagon spanner, tighten the coupling (26) to the fixed coupling (25) (HOTBOX
25/350 only). Operation C in Fig. 5.
• Using two 22 mm/0.86 in hexagon spanners, replace the coupling (22) with the coupling (27) (HOTBOX
25/350 only with combined high-pressure cleaner with max pressure up to 200 bar/2900 psi). Operation B
in Fig. 5.
WARNING
• The following operation must only be performed by a
SKILLED TECHNICIAN
.
• Contact a SKILLED TECHNICIAN to replace the fitting (28) with the fitting (29) (HOTBOX 25/350 only
with combined high-pressure cleaner with max pressure up to 200 bar/2900 psi). Operation E in Fig. 6.
• Connect the coupling (23) to the coupling (24), tightening well (HOTBOX 25/500 only). Operation D
in Fig. 5.
OPERATION - PRELIMINARY ACTIVITIES
• Making reference to the indications in the relative instruction manual, take the combined high-pressure
cleaner to the workplace and engage any parking brake.
• Move the equipment to the workplace by means of the handlebar (2). If fitted, engage the brake (15) of
the swivel wheel (14).
• Making reference to the indications in the relative instruction manual, connect the combined high-pressure
cleaner to the water supply.
• Completely unwind the high-pressure hose (21) connecting the combined high-pressure cleaner to the
equipment and the delivery hose (32) of the high-pressure cleaner.
• Connect the high-pressure hose (21) to the outlet of the combined high-pressure cleaner. Operation F
in Fig. 7.
• Connect the delivery hose (32) of the combined high-pressure cleaner to the equipment outlet.
Operation G in Fig. 7.
• Making reference to the indications in the relative instruction manual, connect the spray gun to the
Summary of Contents for HOT BOX Series
Page 2: ...1 2 3 11 4 7 30 7 4 7 6 4 14 9 5 10 8 HOT BOX 15 200...
Page 3: ...2 12 4 13 15 14 M HOT BOX 15 200 1 17 4 4 18 20 4 19 16...
Page 6: ...7 21 33 31 32 F G H...
Page 64: ...64 RU...
Page 67: ...67 RU RAEE 2012 19 UE 0 1 1 1...
Page 68: ...68 IEC 60364 1 30 A 30 12 12V 5 10 32 8 ft 1 5 230 50 12 12 V 60 2 4...
Page 69: ...69 RU 1 0 1 TotalStop TotalStop 0...
Page 70: ...70 50 19 in 2...
Page 71: ...71 RU 24 40 C 1000 3281 ft...
Page 74: ...74 21 8 HOTBOX 15 200 2 6 8 HOTBOX 15 200 2 30 7 200 500 1 1 7...