background image

 

  IE-LOG-S5141-01 

Start / stop by magnet 

The function must be enabled from the PC before. If only switching OFF by magnet is enabled, 

it is of course necessary to switch ON the logger from the computer. 

Notice: 

It is not possible to combine this function with function reset of MIN/MAX values by 

magnet! User software enables to select only one of them. 

 
 

Switching the logger ON by magnet 

Plug magnet to guide slots from logger front side and wait approximately 1 s for decimal point 

appears right on LCD upper line. After appearance it is necessary immediately (till indication point 
is displayed) to remove magnet from guide slots and logger switches ON. 

 

 

 

 

Switching the logger OFF by magnet 

The procedure is identical with the above procedure for switching ON. If decimal point does not 

appear after 1 s, it is necessary remove the magnet and repeat the procedure. 

 

 

Reset of MIN/MAX values by magnet 

Function enables to clear MIN/MAX values by magnet without using computer. It is necessary 

to enable the function from the PC software before. 

Notice: 

It  is  not  possible  to  combine  this  function  with  function  of  switching  logger  OFF  by 

magnet! User software enables to select only one of them (or none). 

 

Plug magnet to guide slots from logger front side and wait approximately 1 s for decimal point 

appears right  on  LCD upper line.  After decimal  point appearance it is  necessary  immediately (till 
indication point is displayed) to remove magnet from guide slots. Reading CLR MIN MAX appears 
for several seconds and MIN/MAX values will be cleared. 

 

 

 

 
 
 
 
 
 

Summary of Contents for S5141

Page 1: ...LOGGER S5141 Three channel 0 5 Vdc datalogger with internal temperature sensor and display Instruction Manual...

Page 2: ...nction Also memory alarm mode is selectable when alarm is indicated permanently till alarm memory reset Alarm function is enabled or disabled for each channel individually Logging mode can be adjusted...

Page 3: ...normal environment accordingly to appendix NM AE1 AN1 AR1 BE1 Operational position negligible Logger installation by self adhesive Dual Lock applied to clean flat surface Not allowed manipulation inco...

Page 4: ...er automatic switching ON or disable this option select if record runs permanently or only if alarm is active if alarms are about to be applied set both limits for each measured quantity and enable al...

Page 5: ...the display in usual operation logger switched ON After switching ON the logger all LCD symbols are displayed for checking the display Then actual date and time in logger is displayed for approximate...

Page 6: ...bol is replaced by adjacent symbol hyphen It appears in case all measured values are inside of adjusted alarm limits and data logging therefore does not run Displayed symbol indicates logger is ON If...

Page 7: ...lled in non cyclic logging mode logger is switched OFF and message MEMO FULL appears on the LCD It appears also if logger is operated with switched OFF display New initialization of logger can occur i...

Page 8: ...ogger OFF by magnet The procedure is identical with the above procedure for switching ON If decimal point does not appear after 1 s it is necessary remove the magnet and repeat the procedure Reset of...

Page 9: ...cially the real time clock in logger Attention inserted battery with incorrect polarity causes logger damage put the lid back again and screw four screws Be careful to have the rubber sealing properly...

Reviews: