COMESTERO GROUP
M21/03.02
Rev.02
of 25/09/03
Page 25 of 34
service time). When other coins are added, the signal duration is increased proportionally to the
value of the coins added.
The validator manages a display that visualizes the introduced coins until the basic cost is reached
and then it visualized the time expressed in seconds or minutes.
An output signal is provided to give a notice of the expiry of the available time: the notice time is
adjustable.
There is also an input signal (PIN 6) called economizer that stops the time and suspends the
relevant output control. When this signal is disabled, the validator will enable the service and the
time count again.
By means of the portable programmer the following operations can be carried out:
-
Enabling the counting of the introduced coins
-
Setting the basic service cost (P1)
-
Setting the minimum amount to be added to have additional time (P2). If P2 is not defined, to
have extra time, another amount corresponding to the service cost shall be entered
-
Defining the counting and visualization time unit (seconds or minutes)
-
Defining the service duration ranging from 1 to 255 seconds or 1 to 255 minutes (+0 – 2%)
according to the time unit selected
-
Setting the notice signal time (always expressed in seconds)
-
Enabling the economizer actions
PIN OUT OF RM5 X 30 VALIDATOR 10 PIN CONNECTOR
Pin No.
Meaning
Pin No.
Meaning
1
Gnd
6
Time inhibition/stop
2
+12-24 Vdc
7
Display Clock
3
Display Data
8
Timed output
4
Display Enable
9
Notice
5
N.U.
10
N.U.
R
R
M
M
5
5
X
X
3
3
R
R
:
:
O
O
N
N
R
R
E
E
Q
Q
U
U
E
E
S
S
T
T
P
P
R
R
O
O
G
G
R
R
E
E
S
S
S
S
I
I
V
V
E
E
T
T
I
I
M
M
E
E
R
R
The only difference with RM5x30 version is that the timed signal will be given only on customer
request by pressing a button.
PIN OUT OF RM5 X 3R VALIDATOR 10 PIN CONNECTOR
Pin No.
Meaning
Pin No.
Meaning
1
Gnd
6
Time inhibition/stop
2
+12-24 Vdc
7
Display Clock
3
Display Data
8
Timed output
4
Display Enable
9
Notice
5
Credit request
10
N.U.