![Comelit SDVR004A Manual Download Page 42](http://html1.mh-extra.com/html/comelit/sdvr004a/sdvr004a_manual_2639978042.webp)
41
“OFF”, “5s
”
,
“
10s
”
,
“
30s
”
and
“
60s
”
. If you choose “OFF”, the alarm will not be triggered
in any case.
5.6.2 DURATION
This function sets the duration of the recording time after alarm recording is activated.
Options include “30s, 1min, 2min and 5min”.
5.6.3 BUZZER
This function sets the buzzer calling time when the alarm is triggered. Options include OFF, 5
seconds, 10 seconds, 30 seconds and 60 seconds. If you choose “OFF”, the buzzer will not be
triggered whatever happens.
5.6.4 PRERECORD
It sets the record time of duration before alarm is activated. Preview recording time setup: OFF
and 5 seconds.
5.6.5 EXCEPTION
The Tool Bar
System Setting
Alarm
Exception Alarm
[>>] button will bring up the
dialog window where you can set buzzer and I/O
output for HDD Full, HDD Loss and Video Loss.
HDD FULL: you can set buzzer alarm and I/O
output alarm when there is little space for HDD to
recording. Options include “OFF”, “1G”, “5G”,
“10G”, “1 hour”, “5 hours”, “10 hours” and “20
hours”.
HDD LOSS: “ON” indicates that the relevant alarm will go on if there is no HDD and an icon
“
” will be displayed on the left bottom of channel 1 in the live view.
VIDEO LOSS: “ON” indicates that the relevant alarm will go on when one channel has no
video input.
Note: if the
buzzer alarm
in section
5.6.3
or
I/O alarm
in section
5.6.6
had turned off, they
will not be triggered in any case.
5.6.6 I/O ALARM
The Tool Bar
System Setting
Alarm
I/O Alarm
[>>] button will bring up the
dialog window where you can set I/O Alarm,
Output, Record, Buzzer, Prerecord and Email.
CHANNEL: select the channel you need to setup.