![Comelit SDVR004A Manual Download Page 27](http://html1.mh-extra.com/html/comelit/sdvr004a/sdvr004a_manual_2639978027.webp)
26
A. Connection
1) Connect the control line of the speed dome camera to the RS-485 interface of the DVR.
Make sure that A and B are matching.
2) Connect the video line of the speed dome camera to video input of DVR.
3) Activate the speed dome camera.
B. Preparation
1) Set the control address of the speed dome camera and choose relevant control protocol.
2) Switch the current frame to the corresponding display channel.
C. Operation
Double-click the right mouse button to enter tool bar menu under real-time monitoring frame,
and choose “PTZ” or push “ENTER” key to enter the control frame.
Under PTZ control frame press the quad [
] button or right click and an icon “
” will
appear at the top right corner of the screen.
[PTZ Direction Control] Under PTZ control frame, move the mouse to the upper, lower, left
and right locations of the current frame and this time, left click and hold the mouse. Enter the
control area of the corresponding location.
In “ ” mode, use the mouse or the [
▲
] [
▼
] [
◄
] [
►
] buttons on the remote control front
panel to control detection. You can also use Rewind Button
◄◄
and Fast Forward Button
►►
to change magnification.
[SPEED] Regulate the rotating step length of the PTZ by using the slide bar. This function is
mainly for the controlling direction operation. The bigger the value is, the faster the rotational
speed is, with values ranging from 0~63.
[IRIS
-
, IRIS +] Regulate the diaphragm.
[FOCUS
-
-
-
-
, FOCUS+] Bring objects into focus finely.
[ZOOM
-
-
-
-
, ZOOM+] Zooms the Lens in and out. Magnification can be changed by using the
mouse wheel under the current frame.
[MODE]
<Auto scan> controls the automatic scanning of the speed dome camera from left to right
boundary after starting.
<Limit Scan> controls the limit scanning of the high speed dome after starting.
<Patrol> runs the patrol scanning of the high speed dome after starting.
<Pattern> runs the pattern scanning of the high speed dome after starting.