Comelit KSW3207LU Technical Manual Download Page 9

APN:

Connect to WiFi?

<     Ok:

    >

Select network:
Searching...

Password:
123456

9

 

f

Enter the APN (Access Point Name) of your service provider; this will be used to enable data traffic for the SIM card.

 

f

Press Enter/Confirm to confirm.

Connect to Wi-Fi?

The second step in the installation wizard allows connection to a Wi-Fi network. 

 

f

Enter the menu by pressing Enter/Confirm.

The control panel will scan the area to search for all available SSIDs. 

 

f

Select the desired network using the navigation keypad and confirm with Enter/Confirm.

If the network is password-protected, the control panel will ask you to enter it.

 

f

Enter the password using the alphanumeric keypad and confirm by pressing Enter/Confirm.

As an option, you can let the control panel generate its own access point (with its SSID and the corresponding password). 

Scroll through all the Wi-Fi networks and select the option “HOLD ACC.POINT”. This function allows the Wi-Fi IP cameras to be 

connected directly to the control panel.

Summary of Contents for KSW3207LU

Page 1: ...TECHNICAL MANUAL EN SECUR HUB...

Page 2: ...ware sett 52 False code 53 Alarm reset 53 Memory reset 53 Save log in out 53 Menu timeout 54 FW download 54 Walk Test opt 55 Chime duration 55 Warning This Comelit product was designed for use in the...

Page 3: ...plate 2 1 2 3 1 4 5 8 7 6 10 11 9 1 LCD CAP SENSE front panel 2 Microphone 3 Micro USB connectors 4 Battery 5 Battery connector 6 Loudspeaker 7 2G 3G module connector 8 Tamper switch 9 RJ45 Ethernet c...

Page 4: ...4 Installing the LAN module Installing the 2G 3G module 2 1 2 1 3 2 1 Replacing the backplates...

Page 5: ...ation channels you intend to use the control panel should be fitted so as to offer good GSM or WiFi signal strength You will need to consider the availability of electricity mains and Ethernet connect...

Page 6: ...6 Installing the wall mounting backplates Installing the desk base 2 1 3 2A 1A 3A 2 1 3 5 4 6...

Page 7: ...the system is armed steady or that it is not ready to arm flashing Orange LED indicates a fault in the system steady or the presence of isolated bypassed zones flashing Red LED indicates an alarm tam...

Page 8: ...stallation wizard is configuring the GSM 3G module if installed f Enter the menu by pressing Enter Confirm f Enter the SIM number using the alphanumeric keypad and confirm when you have finished by pr...

Page 9: ...n the area to search for all available SSIDs f Select the desired network using the navigation keypad and confirm with Enter Confirm If the network is password protected the control panel will ask you...

Page 10: ...ve an IP address automatically Set manually If you select the manual option use the alphanumeric keypad to enter the IP address and press Enter Confirm Set date time The fourth step in the installatio...

Page 11: ...allowing the user to disarm the system before an alarm is triggered The exit time is the time available once the entry exit zone has been closed following system arming to prevent the alarm from bein...

Page 12: ...one activation will start the Entry delay 1 time program for the selected area This zone type can only activate an alarm if the exit time has elapsed Access This zone type allows the user to activate...

Page 13: ...sing the navigation keypad and confirm with Enter Confirm Set Sounders The seventh step in the installation wizard is used to register RF sounders 1 Enter the menu by pressing Enter Confirm 2 Select t...

Page 14: ...the user to add using the navigation keys and confirm by pressing Enter Confirm If the user has already been registered the menu 1 Reset 2 Delete will be available f Enter the code for the user using...

Page 15: ...p in the installation wizard is used to register accounts relating to the Comelit app on the control panel 1 Enter the menu by pressing Enter Confirm 2 The display shows the first position AppID free...

Page 16: ...or USA standards The option can also be disabled NTP server enable disable options and addresses are available for up to four NTP servers Event log The control panel can log up to 1024 events New eve...

Page 17: ...t which the event occurred Date Date on which the event occurred Who User or device that generated the event Area Area in which the event occurred Where Device on which the event was generated EventID...

Page 18: ...2 standard will be available soon Delete access codes If you confirm this function restores the user and installer access codes to the factory values If you do not confirm the default settings will n...

Page 19: ...s and the message Found appears To find a device f Move on to the Find RF device menu using the navigation keypad and enter the menu by pressing Enter Confirm f Go to the type of device to find using...

Page 20: ...new firmware versions which may be available in the Cloud Bear in mind that the control panel may be set to install new versions automatically as soon as they are available in the Comelit Cloud The wa...

Page 21: ...hen the entry time has elapsed The built in sounder is activated during this additional entry delay period At the end of this entry delay extension the system triggers a full alarm condition the exter...

Page 22: ...each system Default 3 min Double zone If a zone has the Double zone attribute an alarm will only occur if another zone with the Double zone attribute assigned to the same area is triggered within thi...

Page 23: ...dates or date periods Select holiday is used to select the holiday you wish to edit create Holiday description is used to enter a description for the holiday Date interval 1 If the second date interva...

Page 24: ...menu can be used to assign scheduled programs to scheduled armings users outputs or macros Assign to scheduled arming Select schedule programming the scheduled program to be assigned to a scheduled ar...

Page 25: ...emises that an auto arming procedure is about to be activated This period of time can be set to between 0 and 60 minutes Extraordinary no This menu is used to set the maximum number of times an extrao...

Page 26: ...sed to scroll through all possible functions and ENTER alternates between YES NO enabling or disabling the function for that profile Restore default this menu restores the default values for the selec...

Page 27: ...so be used to program sensor settings Programming wireless zones The control panel recognises individual devices each device must be registered in a single zone within the system Each device has a sin...

Page 28: ...zone This menu entry is used to select the zone number for the device that is being acquired The number can be entered directly using the keypad or it can be selected using the Up Down arrows The list...

Page 29: ...occurs at any other time Light 1 After the zone is programmed an output number must be programmed such as exit light 1 in the exit menu This only applies to wired outputs Light 2 After the zone is pr...

Page 30: ...al alarm Gas Gas zones are always active Gas zones generate a gas alarm Flooding Flooding zones are always active Flooding zones generate a water presence alarm The RFH2O device is configured by defau...

Page 31: ...rm zone the only difference is that a specific alarm event will be sent to the alarm receiving centre Ent T P1 P2 Zones with this attribute will only launch the entry delay if violated during partial...

Page 32: ...his menu entry is used to assign one or more cameras to the zone for video alarm verification Delete zone this menu is used to delete a zone from the control panel memory A message DELETE ZONE XX will...

Page 33: ...quisition time used to set the time interval within which the alarm pulses will be taken into account Configuration includes a setting for the Units seconds or minutes and a unit multiplier Alarm puls...

Page 34: ...HT key LEFT key The direction keys should be associated with a number and the corresponding action can be selected in the same way as the F keys The direction key combination is activated by pressing...

Page 35: ...buzzer sound if arming was not successful Show status This menu is used to set the period of time after which the system status is removed from the display The possible options are as follows Unlimit...

Page 36: ...em waits for acquisition of the device with the output number flashing The installer can at this point register the sounder or enter the ID code for the device See appendix A If no devices are detecte...

Page 37: ...the alarm Zone status The output follows the status of the zones Remote output 1 After programming an output with this type you need to confirm a time between 0 and 255 sec 0 indicates that the output...

Page 38: ...f default then the down arrow Command URL This menu is used to edit and or enter a URL command that is an HTTP string generated by third parties and copied in the corresponding Sounder Output menu she...

Page 39: ...be entered directly using the keypad or it can be selected using the arrows The system will always suggest the first available position with a logic of filling available spaces Edit repeater Descript...

Page 40: ...eys can be used to enter the number directly Default setting 1 Areas description Select area This menu is used to enter a description for the area and for its partitions P1 and P2 The default name for...

Page 41: ...e selected recipient Entering an email address automatically enables the email protocol for that recipient IP address this menu option is used to enter the IP address of the selected recipient This me...

Page 42: ...ion report the first event group is shown at the top of the display for example Alarms group There are 16 positions corresponding to the positions of the addresses of the first 16 recipients at the bo...

Page 43: ...ng event Technical programming used to customise voice messages for the technical programming event System operation group used to customise voice messages for each group event Exclude zone group used...

Page 44: ...quired The possible options are as follows Handshake Yes Kissoff Yes Handshake Yes Kissoff NO Handshake NO Kissoff Yes Handshake NO Kissoff NO The default setting is NO NO TWO WAY audio User audio use...

Page 45: ...tandard DC 09 Manual test This menu is used to select which recipients will be made available in the Communications test user menu Enabled recipients can be tested manually here via the Communications...

Page 46: ...mail header can be entered here The text scrolling function allows entry of up to 50 characters Backup this menu is used to enable the email App and ARC backup channel The backup channel is 3G for pro...

Page 47: ...l panel to a WiFi network You can browse a list of available networks using the Up Down arrows and after selecting the correct network enter the password A confirmation message is shown after connecti...

Page 48: ...ing entry time when the option is disabled no buzzers will be activated during entry time Exit buzzer the buzzer is activated during exit time when the option is disabled no buzzers will be activated...

Page 49: ...the arming program to be created or edited The UP DOWN arrow can be used to move through the list ENTER is used to access the arming program configuration steps Description this menu entry is used to...

Page 50: ...val from 00 01 to 23 59 Default 21 min Anti jam RF network jamming interference can be detected by the control panel The detection function can be enabled or disabled using this menu entry Green LED T...

Page 51: ...p to 10 Macros Each macro can trigger 15 actions The actions may be as follows Arm system Disarm system HH MM wait time in hours and minutes before continuing to the next step MM SS wait time in minut...

Page 52: ...Wait MM SS wait time in minutes and seconds before continuing to the next action Output ON activation of an output Output OFF deactivation of an output URL commands Please refer to Radio outputs on pa...

Page 53: ...soon as the sounder audible alert emission time has elapsed Code When this option is selected the system will reset the alarm as soon as a valid disarming code is entered on the system Memory reset T...

Page 54: ...install As with the previous option but without limitations on the download channel which can also be 3G TCP auto downl With this option selected the system will automatically check whether new firmw...

Page 55: ...zone is confirmed via an audible signal Indoor sounder activation of the walk test zone is confirmed via a short audible signal emitted by the indoor sounder External sounder activation of the walk te...

Page 56: ...2 a edizione 06 2022 cod 2G40002649 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...