Maintenance
Tamper mask
Maintenance
Default management
Maintenance
Assign codes
Units: 00 of 15
↓
For missing IDs
18
Tamper mask
After enabling this option, you can remove the control panel from the backplate and then exit the technical menu without
triggering a 24H tamper alarm. It is therefore possible to use the control panel from the user menu by “masking” the tamper
signal. As soon as the control panel is closed again, the tamper check is reactivated and the next time the panel is opened the
corresponding alarm will be triggered.
Default management
This menu entry allows the installer to restore the control panel factory settings.
• Load default:
if this function is selected, the system will ask you to select one of the following setting options:
◊ default Comelit:
this default setting does not conform to EN50131 standards.
-
Delete access codes?
If you confirm, this function restores the user and installer access codes to the factory values. If
you do not confirm, the default settings will not result in all user codes being deleted.
-
Delete RF devices?
If you confirm, this function deletes all paired RF devices. If you do not confirm, this will prevent all
RF devices from being deleted while the default settings are loaded.
◊ Standard EN:
this setting, which conforms to the EN50131 Grade 2 standard, will be available soon.
-
Delete access codes?
If you confirm, this function restores the user and installer access codes to the factory values. If
you do not confirm, the default settings will not result in all user codes being deleted.
-
Delete RF devices?
If you confirm, this function deletes all paired RF devices.
• Codes to default:
this function restores the user and installer access codes to the factory values.
• Delete RF devices:
this function deletes all paired RF devices. If you do not confirm, this will prevent all RF devices from
being deleted while the default settings are loaded.
• Default HW option:
this menu entry allows you to select which default setting options will be restored when a hardware
default is applied.
•
Reboot:
this function is used to restart the control panel.
Assign codes
This menu is used to activate the RF devices that have been registered on the control panel using only the device ID code.
Access this menu to browse the list of devices which are still suspended (only ID registered).
f
Move on to the Assign codes menu using the navigation keys and enter the menu by pressing Enter/Confirm.
Within this menu, the control panel is "receptive" to the registration of signals originating from devices which are included in the
"suspended” list. When a signal originating from a valid device ID reaches the control panel, the device is saved and the index of
paired devices is increased. When all suspended devices have been paired, the message “Completed” appears.