18
18
EN
3
4
5
6
7B
7A
1
2
140-145 cm
115-125 cm
1
2
3A
3B
3C
4
Art. 2608
Cannot be used for the intercom function.
The door-entry phone should always be mounted using Art. 1214/2C as
illustrated in connection diagram BK/FIC on page 95.
1
Privacy function indicator.
2
3-position ringtone/Privacy service selector:
High position: Maximum ringtone volume.
Middle position: Medium ringtone volume.
Low position: Privacy function activation.
Privacy service means exclusion of the call ringtone from the external
unit and switchboard; activation of the Privacy function is signalled by a
red indicator appearing at the top right-hand side).
3
Trimmer for adjusting the microphone volume.
4
User
code
programming microswitches.
5
System connection terminals:
L L
Bus line connection.
CFP CFP
Floor door call input.
P1 C1
Button P1 terminals for various purposes (contact C. NO 24 V -
100 mA max.) (remove CV1 and CV2, see variant SB/X3 on page 97).
S+ S-
Terminals for call repetition device.
6 CV1 CV2 Jumpers to be removed in order to have potential-free C.
NO contact on button P1.
7A/7B
JP1
Jumpers for selecting the switchboard call (position C) / generic
actuator (position A) function of button P1.
Description of buttons:
A
Key button.
P1
Button P1 for switchboard call / generic actuator / button for various
purposes present on terminal block (P1 C1).
Clean using a damp cloth. Do not use alcohol or other aggressive
products.
Installing door-entry phone Art. 2608