Description of the 10-pole terminal block: 

Terminal reference 

Description

 

L1+ 

 

“+” Power supply 

L1- 

 

“-” Power supply  

SHLD 

 

Shield 

COM+ | Dt+ 

(2) 

“+” remote box communication line 

COM- | Dt- 

(2) 

“-” remote box communication line 

NC 

 

Not connected 

 

Caution: 

 

The type of cable to use for electrical connection depends on the unit to which it is connected. For further 
information, please refer to the manual for the device supplying power to the detector. 

 

Description of the 9-pole terminal block: 

Terminal reference 

Description

 

TL+ 

(2) 

“+” remote box radio control input 

TL-/K- 

(2) 

Remote box earth connection 

K+ 

(2) 

“+” remote box key input 

AL NO 

 

Normally open alarm relay contact  

AL COM 

 

Alarm relay common contact  

AL NC 

 

Normally closed alarm relay contact  

FTL NO 

 

Normally open fault relay contact  

FTL COM 

 

Fault relay common contact  

FTL NC 

(1) 

Normally closed fault relay contact  

 
1.  If the detector enters fault status, the relay contact opens. 

2.  For connection  of the remote box, unshielded 2 x 2  x 0.5 mm2 cables are recommended, for COM+/COM- and 

TL+/TL- respectively. The K+ terminal is connected by means of a wire from a 2 x 0.5 mm2 cable. 

COMMISSIONING 

A.4. 

MAIN STEPS 

Commissioning takes place by means of the following steps: 

Step 

Step description 

Powering up the E / R part 

Activating the laser pointer (press the button) 

Deactivating the laser pointer (press the button) 

10 

Automatic calibration startup (1) 

11 

Alignment check startup (2) 

12 

Reflector masking 

13 

Alignment check completion 

14 

Alarm check 

1.  This function starts up automatically when the laser pointer is deactivated. 
2.  This function starts up automatically following a successful automatic calibration. 

A.5. 

POWERING UP 

Power up the E / R after making sure the power supply provided is compatible with the specifications of the detector; 
please refer to this document and the manual for the detector control panel or the 24 Vdc power supply unit, with the 
output limited to 100 mA per detector. 
Every  time  it  is  powered  up,  the  detector  enters  an  initialising  phase  lasting  10  seconds;  the  end  of  this  phase  is 
indicated by the light-up indicator on the front flashing green. 
 

Summary of Contents for 48BFC000

Page 1: ...1 OPTICAL BEAM LINEAR SMOKE DETECTOR WITH REFLECTOR 3 30 M 48BFC000 Please read this manual before using the equipment and keep it safe for future reference...

Page 2: ...with national installation regulations Make sure both the detector and reflector can be accessed for commissioning and maintenance procedures A 2 2 Rules for the installation site The E R and the ref...

Page 3: ...Securing the reflector 6 Deactivating the laser pointer press button Caution Leave a free area of at least 30 cm around each element installed on the wall A 2 4 Flush mounted base The flush mounted b...

Page 4: ...ified the point indicated by the laser beam The reflector is secured in 2 steps Step 1 securing the safety reflector support Use screws with a maximum diameter of 4 mm to secure the safety reflector s...

Page 5: ...2 x 0 5 mm2 cables are recommended for COM COM and TL TL respectively The K terminal is connected by means of a wire from a 2 x 0 5 mm2 cable COMMISSIONING A 4 MAIN STEPS Commissioning takes place by...

Page 6: ...you press the button to deactivate the laser pointer make sure the detector and reflector are not exposed to direct sunlight Note If the orange light flashes after a succession of green pulses carry o...

Page 7: ...ection rating E R part Flush mounted base IP 54 IP 41 Optical parameters Value Wavelength 940 nm Operating distance 3 to 30 m Max E R corner misalignment 0 35 Max reflector corner misalignment 5 Max E...

Page 8: ...one B MAINTENANCE The specific equipment required for servicing the detector is A clean slightly damp cloth for cleaning the E R window and the reflector The alarm test filter to be positioned in fron...

Page 9: ...9...