2.2.2 INSTALLATION CHECKLIST
Working space available for installation and maintenance for each mounting arrangement. Ensure
unrestricted airflow
Ensure earth ground point is within reach of the ground wire
Ensure a power source is within reach of the power cord and the power source has sufficient capacity
Where appropriate, ensure unused RF connectors are terminated
Do not locate the equipment near large transformers or motors that may cause electromagnetic
interference
Reduce signal loss in feeder cable by minimizing the length and number of RF connections
Ensure coax loss is no greater than 25dB
Ensure equipment will be operated within the stated environment (see datasheet)
Observe handling of all cables to prevent damage
Service antennas should be selected based on the type of service area, e.g., indoor antenna for indoor
application, and panel antenna for outdoor application. Additionally, DAS service antennas must be
coordinated with Comba prior to installation, as RFID chips are required to be installed at the Comba factory