
USER
MANUAL
MPD-1611291-A
EXACT-V2 High End Rack Modulator / Exciter
3/10/2017
MPD-1611291-A
Page 69/94
Mute Conditions:
GPI=0: Disabled
GPI=1: Disabled
Mute:
Disable
RFP Warning AGC Protection:
Disabled
RFP Error Protection Cycle:
Disabled
RFP Error Protection – No. of Retries:
3
RFP Error Protection – Delay Between
Retries:
4
RFP Error Protection – Cycle Reset
Time:
60
RF Maintain:
On Input Stream Error: Enabled
Enable Down-Converter:
Enabled
DAP Mode:
Off (standard)
Linear Precorrection Circuits* :
Non-Linear Precorrection circuits* :
Disabled (Bypassed)
Disabled (Bypassed)
Linear DAP Mode:
Non-Linear DAP Mode:
Static (DAP is disabled)
Static (DAP is disabled)
Linear DAP Time_Out:
Non-Linear DAP Time_Out:
20 min
10 min
Primary Clock:
Internal
Secondary Clock:
Internal
PPS Source:
Onboard GPS
PPS Interface:
Output
PPS Edge (RFU):
Rising
Warm-Up Time (Before 10MHz
Synchro):
Enabled
GPS Antenna Voltage:
3.3 VDC
Absolute Reference Time:
GPS
Time and Date Setting:
Manual
Power Measurements:
(not changed by default command)
Active
FWP Input Type:
(not changed by default command)
RF input
FWP Coupler Attenuation:
(not changed by default command)
0 dB
Nominal Power:
(not changed by default command)
0 dBm
Min FWP Error:
(not changed by default command)
80 %
Min FWP Warning:
(not changed by default command)
90 %
Max FWP Warning:
(not changed by default command)
110 %