InteliCharger 240 24 Reference Guide
17
7 Technical data
Nominal input voltage
115 / 230V
AC
Input voltage range
90–135 / 180–305V
AC
Inrush current (V
N
and I
N
load)
≤ 16 A, ≤ 5ms
Frequency
47–63 Hz ± 6 %
Input current (115 / 230 V
AC
)
3.3 / 2.2 A
Internal fuse
6.3 A
Recommended external fuse
16 A (MCB curve B)
Input data
Output V
DC
/ I
N
24 V
DC
/ 10A
Efficiency (50 % of I
N
)
≥ 88 %
Ripple voltage
≤ 80 mV
PP
Output data
Short–circuit protection
Yes
Overload protection
Yes
Overvoltage output protection
Yes
Reverse battery polarity protection
Yes
Detection of element in short–circuit
Yes
Thermal protection
Yes
Protection
Operating ambient temperature range
-25–+70 °C
Storage ambient temperature range
-40–+85 °C
Max humidity (25 °C)
95 %
IP protection class (EN/IEC 60529)
IP20
Reliability (MTBF IEC 61709)
> 300 000 h
Protection class (with PE connected)
I
Dimension (w×h×d)
112 mm × 114 mm × 136 mm
Weight
approx. 0.85 kg
General data