49
AT THE END OF
THE WORK
13. Grip the handle (2) and raise the seat mounting plate to the
maintenance position (
Fig.3
).
14. Disconnect the battery connector (3) from the main system
connector (4) of the machine (
Fig.9A
- B versions).
15. Disconnect the alternator connector (5) from the main system
connector (4) of the machine (
Fig.9B
- G versions).
16.
Tighten the fuel flow tap (10) by moving the lever (11) in the
direction shown by the arrow (
Fig.10
).
17. Grip the handle (2) and lower the seat mounting plate to the
working position (
Fig.4
).
18. For machine versions with an endothermic engine powered with
LPG, when parking the machine remember to close the cylinder
tap (12) (
Fig.11
).
ATTENTION:
when you have finished working, you are
advised to rotate the recovery tank lid to the maintenance
position to avoid the formation of bad smells inside the tank.
9A
11
1
1
1
4
12
3
10
10
11
9B
1
1
4
5