12
Capricorn II Plus User Manual
Memory Feature
The following values may be displayed (and output via the Capricorn RS232C
Interface Option) on command:
Highest outdoor temperature
Lowest outdoor temperature
Highest barometric pressure
Lowest barometric pressure
Peak wind gust
Highest average wind speed (four-second
average)
Each value is displayed for four seconds and continues until the springloaded slide
switch is reset to either a) clear the memory or b) return to current condition display.
Alarm-Controlled Output Feature
The maximum control signal that may be switched by the Capricorn II’s contact
closure (see “Alarm Feature” above) is 12 volts DC, 100 milliamps.
Input Voltage
115 volts AC +/- 10%, 50/60 Hz (Domestic)
230 volts AC +/- 10%, 50/60 Hz (Foreign)
9 volt DC, for Memory Backup
Console Dimensions
15.25" L x 7.5" W x 6.5" H (39 cm x 19 cm x 16.5 cm)
Weight
Net (console only)
17 lbs/7.7 kg
Shipping
20 lbs/10 kg