Page
38
of
40
FABJET GRAND
Lines in Prints
•
Nozzle blocked in heads (check nozzle test)
•
Incorrect feed step (calibration required)
•
Belt motor coupling loose
•
Air pressure is insufficient
Heaters Not Working
•
Check if inlet power cord is connected
•
Check the set temperature in the controller
Take Up Not Working
•
Take-up switch is not ON
•
Take-up regulator is in OFF position
•
Air pressure is insufficient
Fabric Supply Not Working
•
Supply switch is not ON
•
Fabric roller is not in sensor range
•
Air pressure is insufficient
Negative Pressure Drop/Not Working
•
Adjust through vacuum regulator, if value drop to some points
•
Meniscus vacuum switch is OFF
•
Negative Pressure switch program is disturbed
•
Ink overflowed from sub tank and filled in the reservoir
•
Vacuum is not generated by pump (pump failure)
•
Any ink/air tube is having leakage/cut/loose on fitting joints
•
Vacuum pump connector is loose/open from MMCB