background image

Plug Into

Power Driver

Board 

J-116

Optional

:

Only use the male-to-male 

adapter to re-connect a 

pre-existing cable back 

into J-116

Plug Into

ColorDMD

PWR

J-603

Figure E

J-116

J-604

Route the new ColorDMD 

Power Cable along with 

the existing game cables

for a clean install.

DMD Controller

Board

ColorDMD Ground Cable

securely installed.

Grounding lug sandwiched between

metal bracket and 5/8" black spacer.

Power Driver

Board

Locate the included 4-pin ColorDMD power cable.  One end of the 

cable has a single connector (see Fig. D).  Plug this connector 

into the PWR header (see Fig. C) on the ColorDMD.

Plug the other end of the new ColorDMD Power Cable (see Fig. D) 

into J-116 on the WPC Power Driver Board (see Fig. E).  If an 

existing cable is currently plugged into J-116, disconnect it before 

connecting the ColorDMD power cable

.

If you disconnected a cable from J-116 in the previous step, use 

the included male-to-male adapter to re-connect this cable to 

the available center connector on the ColorDMD power cable 

(see Fig. D).  Otherwise, do not connect the male-to-male 

adapter and store it in a safe place.

9

10

Figure D

11

STEP

STEP

STEP

TIP

ALL RIGHTS RESERVED - US PATENT 8,773,452 B2 - COPYRIGHT 2016 - COLORDMD DISPLAYS LLC

Summary of Contents for CHROMA eDP WPC

Page 1: ...D from the game and store it in a safe place 1 2 3 STEP STEP STEP Disconnect the DMD power and ribbon cables from the DMD Unplug the DMD power cable from the high voltage A V board J 604 see Fig E and remove this cable from the backbox Congratulations on the purchase of a new ColorDMD display The ColorDMD will enhance your pinball machine by introducing color to the dot matrix display graphics pro...

Page 2: ...protective film from the front side of the new ColorDMD display Use the original DMD mounting hardware from Step 3 to fasten the ColorDMD display to the speaker panel See Fig B for correct stacking order of the hardware Ensure the ground cable lug from Step 7 is sandwiched between metal bracket and one of the 5 8 black spacers 5 6 7 STEP STEP STEP WARNING Electric Shock Hazard To protect against a...

Page 3: ...e connector see Fig D Plug this connector into the PWR header see Fig C on the ColorDMD Plug the other end of the new ColorDMD Power Cable see Fig D into J 116 on the WPC Power Driver Board see Fig E If an existing cable is currently plugged into J 116 disconnect it before connecting the ColorDMD power cable If you disconnected a cable from J 116 in the previous step use the included male to male ...

Page 4: ...he right most ColorDMD Menu button See Fig F to customize the display settings Continue pressing the button to advance to the MOUNTING menu Next use the Toggle Selection Up button to change the setting to WPC 15 STEP Double check for proper alignment of all cable connections For additional information regarding display settings please visit our website at www colordmd com STEP STEP Press the right...

Reviews: