Service Menu VIBA X.30
2021-05-05 Seite 19/21
5.7
SET DOOR MENU
SET DOOR
YES NO YES
DOOR
START
UCLMP
Setting of door options.
DOOR
= Door opens automatically after the mixing.
START
= Mixing procedure can be started by closing
the door.
UCLMP
= Manual release of mixing unit is permitted
when the door is open.
5.8
SET LANGUAGE MENU
SET LANGUAGE
ENGLISH
Press E to quit
SELECT
Language setting for the main menu
SELECT
= Language selection
The service menu language cannot be modified.
5.9
SET TIME & DATE
SET TIME&DATE
10:15:28
01.05.2019
+
-
>
Setting the date and time
+
= Increase value
-
= Decrease value
>
= Next digit
The internal clock is stopped during the time setting.
5.10
OPERATING HOURS
OPERATING HOURS
TIME: 01600:32
+
-
>
Enter the operating hours of the machine.
+
= Increase value
-
= Decrease value
>
= Next digit
When the control panel is replaced, the operating hours of the ma-
chines can be set here.