Installation and assembly
41
6.7 Wiring
For a fail-safe operation of the Collamat C4300/C7300 a few important
point have to be remembered:
Installation only by skilled labor.
Ambient air temperature, dirt, dust, splash water
Respect the specific mounting directions of the optional
conveying equipment and other user specific subassemblies.
Respect the Collamat C4300/C7300 installation- and
mounting -
directions
Electromagnetic/electrostatic interfering fields
Directives of the safety chain
Electromagnetic/electrostatic interfering fields can lead to unexpected
errors in the unit. Clumsy wiring during the installation phase or while
servicing a unit is often the cause of an unstable unit.
Therefore - the following points have to be observed while working on
the wiring:
Separate installation of control- and power- lines
Use shielded cables
Ground all peripherals (PE)
Use peripherals witch fulfill the EMC directives
Use additional power filters (dirty power line)
Connection of good scanner and optional incremental
encoder – see chapter 9 – Conne buildup
6.8 Inspection on conclusion of installation work
Check that the installation is correct.
Check the operator's own safety devices for completeness,
condition and safe functioning.
Instruct operating personnel and establish the place on the
machine where the operating instructions are to be kept.
After complete installation and checking of the machine and
instruction of the operating personnel, the machine is ready
for start-up.