background image

12

8.  

TECHNICAL SPECIFICATION

 

Physical Data

 

Height (closed, handle up) 

310mm

 

Height (closed, handle down) 

267mm

 

Height (cover fully open) 

483mm

 Width 

216mm

 Depth 

292mm

 

Weight (empty and unpacked)  8.7 Kg Nominal.

 

Fixtures / Fittings

 

Power Connector 

3-pin shrouded plug.

 

LO/Off HI, Switch 

3-position DPDT toggle switch with centre-off position.

 

Power On LED 

Green LED / Red in Fault condition.

 

Boil Cycle LED 

Yellow LED

 

Heater On LED 

Yellow LED

 

Latch (main case + cover) 

Self-locking quick-release toggle clip + hook.

 

Lifting handle (cover) 

Fold down Heat proof Grip.

 

Tap 

Spring loaded ‘pull to operated’ water valve.

 

Pressure / vacuum relief 

Dual action air valve pre-set at 0.3 psi (20.7 mb).

 

Electrical Data

 

Supply Voltage 

28Volts DC

 

Supply Current 

30A

 

Power Consumption 

800Watts (nominal).

 

Heater Type 

Cartridge type 200W each 4 off mounted in heater block on

 

 

underside of the outer container.

 

Heater Control 

On / Off switching determined by temperature sensor using

 

 

thermal feedback.

 

Heater Safety Cut-out 

Boil dry temperature sensor operating at 172 °C. Non repairable

 

 

thermal fuse set operating at 175°C.

 

Performance Data.

 

Heating (water only) 

3 litres of water will boil in 75 minutes (max) from an ambient

 

 

temperature of 21°C at sea level.

 

Heating (R water) 

Temperature of up to five pre-cooked meals and 1.18 litres

 

 

water will be raised to between 66°C and 71°C from an ambient

 

 

temperature of 21°C. Cooking time dependent on meal.

 

Heating Retention 

Better that 45% of selected heating range at three hours after

 

 

HW & R is turned off with the cover closed and latched.

 

Heating Range (LO) 

66 - 71°C at sea level.

 

Heating Range (HI) 

Initial ‘One Shot’ Boil, then cools to 82 - 88°C at sea level.

 

Automatic Shutdown 

Power supply voltage less than 24Volts DC or Boil Dry detected.

 

Overvoltage Protection 

Power supply voltage greater than 32Volts DC.

 

Environmental Data.

 

Temperature (operating) 

Between -32 and 60°C.

 

Temperature (storage) 

Between -51 and 71°C.

 

Humidity (storage) 

Between 10 and 90%.

 

The Ingress protection rating for this product is classified as IP53D. 

Summary of Contents for Electrothermal RAK30 HW & R

Page 1: ...Heater Water Ration HW R RAK30 One shot boiling unit N S N 7310 99 362 3482 Instruction Manual M7819 Version 4 4...

Page 2: ...l Support 21 Section 12 Notes 22 The copyright of this instruction manual is the property of Cole Parmer Limited This instruction manual is supplied by Cole Parmer Limited on the express understanding...

Page 3: ...of water from 20 C in just over 30 minutes when switched to the HI setting After boiling the water will cool slowly until a temperature approaching 86 C 3 C is reached The HW R will then continue to o...

Page 4: ...n normal domestic waste Caution Hot surface Refer to Instruction Manual Recyclable Packaging Material 4 2 SYMBOLS AND USING THIS INSTRUCTION BOOK 2 1 Throughout this Instruction book the following sym...

Page 5: ...tion afforded by the equipment may not be preserved and the guarantee invalidated 3 SAFETY INFORMATION This product has been designed for safe operation when used as detailed in accordance with the ma...

Page 6: ...em No Description Qty 1 Instruction Book 1 2 RAK3 0 HW R unit 1 For future reference please record your products Serial and Model Numbers Serial Number Model Number Page 6 of 24 M7819 Issue 4 2 4 UNPA...

Page 7: ...e relevant vehicle installation data The three studs 5 16 x 10 UNC thread provide on the HW R are for location only and not for sole mounting purpose The recommended method for mounting of the HW R is...

Page 8: ...ertificate are available from your distributor of Bibby Scientific products or you may copy and enlarge from Appendix A of this instruction book Bibby Scientific s Electrothermal branded product range...

Page 9: ...nt components of the product 7 PRODUCT OPERATION 7 1 The RAK30 HW R has been designed for easy operation The illustrations below show detailed layouts of this product 1 Main Case Assembly 2 Outer Cont...

Page 10: ...cle completed Heater is off Water is in process of cooling down to approximately 86 C This takes approximately 1 hour 4 Power On Boil Cycle Heater On LED On Green LED On Yellow LED On Yellow One shot...

Page 11: ...ower On Boil Cycle Heater On LED On Green LED Off LED On Yellow Water is heating towards set point of 68 C 2 Power On Boil Cycle Heater On LED On Green LED Off LED Off Water is at 68 C set point Heate...

Page 12: ...ed by temperature sensor using thermal feedback Heater Safety Cut out Boil dry temperature sensor operating at 172 C Non repairable thermal fuse set operating at 175 C Performance Data Heating water o...

Page 13: ...holes or large dents Container has damage preventing safe usage c Inspect for dirt grease oil or food debris d Inspect for signs of corrosion 3 Outer Container a Inspect for physical damage such as h...

Page 14: ...Inner Container a Check food has been removed b Inspect for dirt grease oil or food debris 12 Outer Container a Check water has been removed b Inspect for dirt grease oil or food debris 13 Main case...

Page 15: ...to the surface finish DISHWASHING COMPOUND Discard hand dishwashing compound heated water solution inn accordance with the disposal instructions NOTE With the HW R mounted in the host vehicle it is no...

Page 16: ...over perform the procedure in sub paragraph 5 2 16 9 2 15 Return the HW R to normal service Cleaning the Cover 9 2 2 Remove any loose food from the inner and outer containers by pre scraping 9 2 3 Fil...

Page 17: ...are to avoid splashing the control panel 9 2 27 Allow main case to air dry Page 17 of 24 M7819 Issue 4 2 9 2 16 To prevent the ingress of liquid into the interior of the cover block off the small stea...

Page 18: ...ining plate using an easily removable means e g tapered wooden peg of suitable size 18 Page 18 of 24 M7819 Issue 4 2 Sanitising the HW R unit 9 2 28 Fill the outer container with clean potable water u...

Page 19: ...tap drain off the food service disinfectant heated water solution from the outer container 9 2 43 Half fill the outer container with clean potable water and rinse off all traces of food service disin...

Page 20: ...f the HW R to cool Refill with fresh potable water 4 Electronics over temperature Switch off the HW R to cool If fault is repeated have HW R serviced Fault most likely in ambient conditions over 35 C...

Page 21: ...al sales specialist or email cpspares coleparmer com to enquire about available spares Please visit www electrothermal com for a full list of available accessories 11 CUSTOMER AND TECHNICAL SUPPORT Fo...

Page 22: ...12 NOTES 22...

Page 23: ...23 12 NOTES...

Page 24: ...Cole Parmer Ltd Beacon Road Stone Staffordshire ST15 0SA United Kingdom Tel 44 0 1785 812121 Email cpinfo coleparmer com Web www electrothermal com...

Reviews: