Cole Parmer EH-200 Series Instruction Manual Download Page 5

5

 

3.

SAFETY INFORMATION

This product has been designed for safe operation when used as detailed in accordance

with the manufacturer’s instructions.

NOTE: 

Failure to use this equipment in accordance with this instruction manual may

compromise your  basic safety  protection afforded  by the  equipment and  may invalidate 

the warranty / guarantee. The warranty / guarantee does not cover damaged caused by

faulty installation or misuse of the equipment.

3.1.

 

Prevention of Fire and Electric shock. 

To prevent a risk of fire or electric shock, 

do not 

open your product case 

without authorisation. Only qualified Service personnel should attempt to 

repair this Controller.

 

Only replace fuses with the type as listed in Technical Specification section

 

(See fuse type and rating).

 

Ensure the Mains Power Supply conforms to rating found on the data plate 

located on the base of this product.

 

Never 

operate this equipment  without connection to earth / ground. Ensure 

the mains supply voltage is correctly earthed / grounded in accordance with 

current area legislation.

 

3.2.

 

General Safe Operating Practice. 

Always follow good laboratory practice when using this Equipment. Give 

due recognition to your company’s safety and legislative health & safety

 

procedures and all associated legislation applicable to your areas of operation. 

Check laboratory procedures for substances being heated and ensure all 

hazards (e.g. explosion, implosion or the release of toxic or flammable gases) 

that might arise have been suitably addressed before proceeding. When 

heating certain substances the liberation of hazardous gases may require the 

use of a fume cupboard or other means of extraction.

 

Ensure equipment is used on a clean, dry, non-combustible, solid work surface 

with at least 300mm suitable clearance all around from other equipment.

 

Do not 

position the product so that it is difficult to disconnect from the mains

 

supply.

 

 

Do not 

touch the heating element or any glass vessel whilst in use

 

 

Do not 

lean or stretch over equipment, glassware and fixings when in use

 

 

Do not 

immerse the controller in water or fluids.

 

Do not 

spill substances onto this unit. If spillage does occur, disconnect 

unit from mains supply and follow instructions as detailed in Section 

‘Maintenance’.

 

Summary of Contents for EH-200 Series

Page 1: ...Instruction Manual M6895 Version 6 6 Cole Parmer EH 200 Series Macro Kjeldahl Extraction Equipment...

Page 2: ...15 The copyright of this instruction manual is the property of Antylia Scientific Limited This instruction manual is supplied by Antylia Scientific Limited on the express understanding that it is to...

Page 3: ...stainless steel tray and a well ventilated air space Each heating mantle has its own energy regulator incorporating an ON OFF switch and an amber mains to heater neon indicator There is also a mains O...

Page 4: ...or other people The Responsible Body and the Operator should read and be familiar with this Instruction manual in order to preserve the protection afforded by the equipment To prevent injury or equipm...

Page 5: ...th current area legislation 3 2 General Safe Operating Practice Always follow good laboratory practice when using this Equipment Give due recognition to your company s safety and legislative health sa...

Page 6: ...ended during operation The equipment is not spark flame or explosion proof and has not been designed for use in hazardous areas in terms of BSEN 60079 14 1997 Keep flammable low flash point substances...

Page 7: ...gainst the relevant product diagram Applicable to all EH 200 2 EH 200 6 Series products 2 way 6 way Item No 1 Description Instruction manual Qty 1 2 Rack 1 3 Product 1 For future reference please reco...

Page 8: ...ses are fitted Where applicable ensure the correct mains cable fuse if fitted See Technical Specification Section 8 of this Instruction manual 5 5 Check the voltage on the product data label of this u...

Page 9: ...replace and secure the terminal mounting plate Hard wire the free end into a fused isolation unit and fit 35Amp fuses Observation the surface of the heating element of a mantle cartridge will upon re...

Page 10: ...ment before switching on the power supply When first used the surface of the heating element will become slightly discoloured This is due to the dressing in the fabric and will gradually disappear wit...

Page 11: ...m Glass Quick Blow EH 200 2 115 100 300 600 F7A 6 35 x 32mm Ceramic EH 200 2 EU 100 300 600 F5A 6 35 x 32mm Glass Quick Blow EH 200 2 L 500 800 1100 F7A 6 35 x 32mm Ceramic EH 200 2 L 115 500 800 1100...

Page 12: ...HIS EQUIPMENT 9 2 Fuse Replacement The mains fuse holder is located at rear your product Refer to Technical specification Fuse Rating for correct fuse type and rating Turn your product off and disconn...

Page 13: ...xcessive spillage flask fracture invert the mantle and allow it to drain for a minimum of one hour Then place the complete mantle the correct way up in a heated oven at 60 C for a minimum period of 24...

Page 14: ...EMQ3824 68BEX1 Please contact your local sales specialist or email cpspares antylia com to enquire about available spares Please visit www coleparmer com for a full list of available accessories 11 CU...

Page 15: ...ts for laboratory equipment for the heating of materials Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General requirements Class A IEC EN 61010 2 010 2003 IE...

Page 16: ...75 20 EH 200 EH 200 6 L EU MQ3868B EX6 Antylia Scientific Ltd Beacon Road Stone Staffordshire ST15 0SA United Kingdom Ordering Information Warranty Registration India T 91 22 61394444 E info antylia c...