Summary of Contents for 91100-00

Page 1: ...1100 10 Type K 91100 20 Type T Cole Parmer Instrument Company 625 East Bunker Court Vernon Hills Illinois U S A 60061 1844 847 549 7600 847 247 2929 Fax 800 323 4340 www coleparmer com e mail techinfo...

Page 2: ......

Page 3: ......

Page 4: ...PERATING PROCEDURES7 SELF TEST 9 CONNECTING A THERMOCOUPLE 10 SELECTING TEMPERATURE SCALE 14 HOLD FUNCTON 15 CALIBRATION 15 CANCELING A FIELD CALIBRATION 17 FIELD CALIBRATION LOCKOUT AND RE ENABLE 17...

Page 5: ...the following features Operator selection of Celsius or Fahrenheit scale Resolution of 0 1 from 99 9 to 299 9 Four digit LCD Hold feature for temporarily retaining a reading Field calibration capabil...

Page 6: ...HE SPECIFIED 50V RMS CAUTION DO NOT USE OR STORE THIS INSTRUMENT IN MICROWAVE OVENS OR ANY ABNORMALLY HOT OR COLD AREAS CAUTION WEAK BATTERIES SHOULD NOT BE LEFT IN THE INSTRUMENT DEAD BATTERIES CAN L...

Page 7: ...N AREA KNOWN TO BE NON HAZARDOUS AVERTISSEMENT AFIN DE PREVENIR L I N F L A M M AT I O N D ATMOSPHERES DANGEREUSES NE CHANGER LES BATTERIES QUE DANS DES EMPLACEMENTS DESIGNES NON DANGEREUX WARNING TO...

Page 8: ...to 2501 F Type T 250 C to 400 C 418 F to 752 F Out of range display Resolution 0 1 1 autoranging 0 1 from 99 9 to 299 9 1 outside this range Accuracy 99 9 0 2 of reading 0 5 C 0 2 of reading 0 9 F 99...

Page 9: ...ndication Battery Symbol on when 8 to 10 hours of battery life remains Battery symbol blinking replace battery Operating Conditions Stated accuracy 18 C to 28 C 64 F to 82 F Useful range 0 C to 40 C 3...

Page 10: ...limited for intrinsically safe operation in hydrogen atmospheres per Class I Division 1 Groups A B C and D hazardous classified locations for UL per UL913 and CSA per C22 2 No 0 M1982 and No 157 M198...

Page 11: ...n 1 hour of life remaining Selected settings are stored in memory and will remain in memory even after power is turned off or while batteries are being replaced 1 Before changing battery turn instrume...

Page 12: ...LD NOT BE LEFT IN THE INSTRUMENT DEAD BATTERIES CAN LEAK AND CAUSE DAMAGE TO UNIT DANGER VOLTAGES PRESENT AT THE THERMOCOUPLE MAY ALSO BE PRESENT AT THE BATTERY TERMINALS ALWAYS DISCONNECT THE THERMOC...

Page 13: ...AVERTISSEMENT AFIN DE PREVENIR L I N F L A M M AT I O N D ATMOSPHERES DANGEREUSES NE CHANGER LES BATTERIES QUE DANS DES EMPLACEMENTS DESIGNES NON DANGEREUX SELF TEST Press the ON OFF key The thermome...

Page 14: ...roneous readings Thermocouples are color coded by type using the North American ANSI Color Code as follows TYPE COLOR J Black K Yellow T Blue Thermocouple connectors have one wide blade and one narrow...

Page 15: ...mocouple wiring polarity must be correct If readings decrease as the temperature increases the thermocouple wires may be reversed The red wire is negative for thermocouple wires manufactured in North...

Page 16: ...12...

Page 17: ...13...

Page 18: ...tabilize Multiplying the time constant of the probe by 5 will give you the approximate time required SELECTING TEMPERATURE SCALE Select C or F by pressing the C F key Each time the key is pressed the...

Page 19: ...r thermocouple off set error It is not necessary to perform a field calibration to obtain specified meter accuracy Use the field calibration feature to improve thermometer probe accuracy or to compens...

Page 20: ...ng is stable press the CAL key The CAL indicator will stop blinking and the reading will be set to 0 C 32 F The CAL indicator will remain turned on indicating a field calibration is active If Err is d...

Page 21: ...mometer reverts to the default factory calibration The CAL annunciator is now turned off FIELD CALIBRATION LOCKOUT AND RE ENABLE The calibration lockout feature prevents any field calibration changes...

Page 22: ...and momentarily press the ON OFF key Continue to hold the CAL and C F keys for at least 5 seconds 1 2 Re Enable Procedure 1 Turn the thermometer off 2 Simultaneously press and hold the HOLD and the C...

Page 23: ...ot clean with abrasives or solvents Use mild detergents never immerse nor use excessive fluid BATTERIES If there is no display when the thermometer is turned on check condition of the two AA batteries...

Page 24: ...n handle a 5 ft coiled cord and a 316 SS sheath General purpose probes 5 in long x 0 156 in dia with 0 093 in dia tip 3 second time constant Type J 08517 55 Type K 08516 55 Type T 08500 55 Penetration...

Page 25: ...th with 1 4 in dia radiant heat shield 45 second time constant Type J 08517 75 Type K 08516 75 Type T 08500 75 39800 98 Carrying case Hard plastic case with foam insert holds one meter and up to five...

Page 26: ...PROMETTRE LA SECURITE INTRINSEQUE There are no internal adjustments or user replaceable parts If Err followed by the numbers 1 through 9 is displayed see example below return unit for service Note tha...

Page 27: ......

Page 28: ...es and delays contact the seller or Manufacturer for authorization and shipping instructions before returning the product either within or outside of the warranty period When returning the product ple...