Introduction 

Thank you for purchasing the Cole-Parmer MSU-100 Series compound binocular microscope. These economical, 
entry-level upright microscopes are developed for use at schools and laboratories. They offer cordless operation and 
ergonomic carrying grip for added convenience.

Please read this manual carefully before using this product to ensure correct and safe usage: 

• 

The contents of this manual are subject to change without notice 

• 

The appearance of the actual product can differ from the models described in this manual 

• 

Not all equipment mentioned in this manual has to be part of the set you have purchased 

• 

All optics are anti-fungus treated and anti-reflection coated for maximum light throughput

Introduction ____________________________________________________________________ 3
General safety instructions _______________________________________________________ 3

Dangers associated with the operation  ___________________________________________________________3
Photobiological safety LED, important safety instructions  ___________________________________________3
Prevention of biological and infectious hazards  ____________________________________________________3
Disinfection and decontamination:   ______________________________________________________________4
Model with rechargeable batteries  _______________________________________________________________5
Environment, storage and use ___________________________________________________________________5

Models  ________________________________________________________________________ 6
Components of the microscope ___________________________________________________ 7
Preparing the microscope for use  _________________________________________________ 8

Assembling Steps  _____________________________________________________________________________8

Operation  ______________________________________________________________________ 9

Setting up the illumination ______________________________________________________________________9
Place the specimen slide _______________________________________________________________________10
Focusing and slide protection  __________________________________________________________________10
Eyepieces  ___________________________________________________________________________________10
Abbe condenser  ______________________________________________________________________________11
Use of the S100x oil-immersion objective  ________________________________________________________12
Safety device _________________________________________________________________________________12
Illumination __________________________________________________________________________________12

Maintenance and cleaning  ______________________________________________________ 13

Cleaning the optics  ___________________________________________________________________________13
Maintenance of the stand  ______________________________________________________________________13
Changing the batteries ________________________________________________________________________13

Accessories and spare parts ______________________________________________________ 14
Warranty ______________________________________________________________________ 14
 Notes _________________________________________________________________________ 15

Summary of Contents for 78903-90

Page 1: ...Installation and Operating Instructions MSU 100 Series Compound Microscope Model 78903 90...

Page 2: ...omponents of the microscope____________________________________________________ 7 Preparing the microscope for use __________________________________________________ 8 Assembling Steps _______________...

Page 3: ...a cover glass never comes in direct contact with the microscope parts In that case prevention of contamination lies in the handling of the slides as long as the slides are decontaminated before use a...

Page 4: ...based disinfection products for laboratories Before returning a microscope for repair or maintenance through a Cole Parmer dealer an RMA return authorization form together with a decontamination state...

Page 5: ...be between 5 to 40 C and humidity should be within 20 to 80 RH Although the system is anti mold treated installing this product in a hot humid location may still result in the formation of mold or con...

Page 6: ...and the slide The Numeric Aperture N A of the objective is an indication for the resolving power of the objective The total magnification can be calculated by multiplying the magnification of the eye...

Page 7: ...for 3 or 4 objectives B Safety device J Objectives C Tension adjustment K Object stages mechanical stage or clips D On Off switch not visible L Height adjustment lever condenser E Light intensity con...

Page 8: ...r head please pull out the power cord immediately and dry the microscope Assembling Steps Mounting the objectives 1 Rotate the coarse focusing knob to lower the stage to its lowest position 2 Install...

Page 9: ...is lost or damaged choose one with the same specifications Replacement of the Power Cord If the power cord requires replacement ensure that it is suitably rated If in doubt consult your local dealer o...

Page 10: ...ng with a S100x objective you need to lock the slide protection screw D The slide protection screw protects the slide by limiting the travel range of the mechanical stage This way the objectives will...

Page 11: ...h the object stage an Abbe condenser N A 1 25 is mounted The condenser can be adjusted in height by moving the lever beneath the mechanical stage N By adjusting the condenser you can focus the light o...

Page 12: ...er Clean the front lens of the S100x objective 11 Always clean the front lens of the S100x objective with a piece of lens paper that is moistened with a drop of isopropanol 12 Clean the slide after us...

Page 13: ...ust can be removed with high pressured air There will never be dust in the objectives if the objectives are not removed from the revolving nosepiece Caution Cleaning cloths containing plastic fibers c...

Page 14: ...as bulbs batteries fuses cords optical components or any add on accessories such as mechanical specimen holders that are not built into the microscope stage as an integral part of the original manufa...

Page 15: ...______________________________________________________ ___________________________________________________________________________________________________ _____________________________________________...

Page 16: ...2022 Cole Parmer Instrument Company LLC Toll free 1 800 323 4340 Phone 1 847 549 7600 Fax 1 847 247 2929 coleparmer com 1065Y62_M_CP_MSU 100_Series_Compound Microscope_Manual...

Reviews: