JT2002
Auto Range Multimeter
User Manual
43
C. DC Current
Range
Resolution
Accuracy
Overload Protection
600µA
0.1µA
(1.0%+3)
Fuse1: F600mA H 1000V,
Φ
6.35 x 31.8mm
6000µA
1µA
60mA
0.01mA
600mA
0.1mA
6A
0.001A
(1.2%+5)
Fuse2: F10A H 1000V,
Φ
10.3 x 38.1mm
10A
0.01A
Remarks:
When ≤5A: Continuous measurement is allowed.
When >5A: Continuous measurement of less than 10 seconds with an interval of
at least 15 minutes between measurements.