![Cojali 50002002 User Manual Download Page 16](http://html.mh-extra.com/html/cojali/50002002/50002002_user-manual_2635055016.webp)
JT2002
Auto Range Multimeter
User Manual
16
⚠
Warning
To avoid harms to you or damages to the Meter from electric shock, please do
not attempt to measure voltages higher than 1000V although readings may be
obtained.
When measuring high voltage, take extra care to avoid electric shock.
1. Insert the red test lead into the V terminal and the black test lead into the COM
terminal.
2. Set the rotary switch to V; DC measurement is set by default or press BLUE
button to switch between DC and AC measurement mode.
3. Connect the test leads across two points of the object being measured.
The measured value is shown on the display.
Display effective value of sine wave (mean value response).
Input Amplitude: (DC electric level is zero).
Input Amplitude: ≥ range X30%
Frequency response: ≤ 1 kHz