Secure the sliding lens cover using the M3 wing nut.
9
Assembly Instructions (continued)
Insert the four M4x20 mm screws in the mounting holes in the
FOVE-bracket.
4
Attach the M3x25 mm flat head cap screw to the FOVE-bracket
using an M3 hex nut, as shown in step 4 on page 12.
For attaching a DataMan 503 reader to Xpand 15, follow the steps
highlighted below.
1
2
3
Attach the bracket subassembly to the housing subassembly using
four M4x10 mm flat head cap screws. Make sure that the tab on
the sliding lens cover aligns with the M3x25 mm screw on the
FOVE-bracket, as shown in step 6 on page 14.
Attach the FOVE-bracket to the bar light bracket, as shown in
step 1 on page 10.
Check focus and adjust if necessary as described on page 22. To adjust
focus, open the sliding lens cover first. When the focus has been set,
close the sliding lens cover as described in step 7 on page 15.
8
Torque limit:
50 N-cm (4.4