Precautions
Observe these precautions when installing the In-Sight 1400 I/O Expansion Module to
reduce the risk of injury or equipment damage:
•
The 1400 I/O Expansion Module is intended to be supplied by a Listed, Direct
Plug-In Power Unit with a minimum output rated 24VDC, 750mA and marked Class
2, Limited Power Source (LPS). Any other voltage creates a risk of fire or shock and
can damage the In-Sight components.
•
Never connect the 1400 I/O Expansion Module to a power source other than
24VDC, and always use the 24VDC terminal block pins on the I/O module. Any
other voltage creates a risk of fire or shock and can damage the hardware.
•
Do not install the 1400 I/O Expansion Module in areas directly exposed to
environmental hazards such as excessive heat, dust, moisture, humidity, impact,
vibration, corrosive substances, flammable substances, or static electricity without a
protective enclosure.
•
To reduce the risk of damage or malfunction due to over-voltage, line noise,
electrostatic discharge (ESD), power surges, or other irregularities in the power
supply, route all cables and wires away from high-voltage power sources.
•
The I/O Expansion Module does not contain user-serviceable parts. Do not make
any electrical or mechanical modifications. Unauthorized modifications may violate
your warranty.
•
Changes or modifications not expressly approved by the party responsible for
regulatory compliance could void the user’s authority to operate the equipment.
•
The 1400 I/O Expansion Module is intended for indoor use only.
Summary of Contents for In-Sight 1400
Page 2: ......
Page 4: ...Copyright Trademarks Patents ii...
Page 6: ...Regulations Conformity iv...
Page 8: ...Precautions vi...
Page 12: ...List of Figures x...
Page 14: ...List of Tables xii...
Page 26: ...Installation 12...
Page 36: ...Specifications 22...
Page 42: ...Appendix A Configuring Discrete Inputs 28...
Page 57: ......