20 DataMan 200 Quick Reference Guide
DataMan 200 Quick Reference Guide 21
Training the Reader
Training your reader with the expected symbology can decrease the time
required to decode successive symbols. Train your reader by placing a code
in front of it and doing one of the following:
• Press and hold the trigger button for a
minimum of 3 seconds.
• Click and hold the trigger button in
the Setup Tool for a minimum of 3
seconds.
• Click
Train Code
in the Results Display pane.
Training is supported for the Single, Burst, Continuous and Self trigger
modes.
Connect the reader to the Setup Tool to
untrain it and allow it to recognize other
enabled symbologies.
Training Feedback
The middle LED on the reader glows green to indicate that it is currently
trained, or yellow to indicate that it is not trained.
Incremental Training for Multiple Symbologies
If you want to train the reader to recognize multiple symbologies, you
can present a single image showing all the desired symbologies and
perform the training procedure previously described.
If you cannot present a single image showing all the necessary
symbologies, you can enable incremental training on the
Training
tab
of the
Symbology Settings
pane:
With incremental training enabled, you can train the reader using
multiple images showing the symbologies you expect to decode. The
reader will train each new symbology while retaining the existing
trained symbologies.