Precautions

Observe these precautions when installing Checker to reduce the 
risk of injury or equipment damage:

Do not attempt to adjust Checker’s focus when moving parts 
and/or equipment are present.

Use a listed power supply with an output rated 24VDC, at 
least150mA, and marked Class 2, Limited Power Source 
(LPS). Any other voltage creates a risk of fire or shock and can 
damage Checker.

Do not install Checker in locations that expose it to 
environmental hazards such as excessive heat, humidity, 
impact, vibration, corrosive substances, flammable 
substances, or static electricity.

To reduce the risk of damage or malfunction, route all cables 
and wires away from high-voltage power sources.

Do not attempt to modify Checker. Modifications will void the 
warranty.

Getting Help

On-line support is available at 

support.cognex.com

, or you may 

contact Cognex directly:

Additional Information

NOTE:

 This equipment has been tested and found to comply with the limits for a Class A 

digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the instruction manual, 
may cause harmful interference to radio communications. Operation of this equipment in a 
residential area is likely to cause harmful interference in which case the user will be 
required to correct the interference at his own expense.

Copyright © 2005 Cognex Corporation All Rights Reserved

This document may not be copied in whole or in part, nor transferred to any other media or 
language, without the written permission of Cognex Corporation.

The hardware and portions of the software described in this document may be covered by 
one or more of the U.S. patents listed on the Cognex web site 
http://www.cognex.com/patents.asp. Other U.S. and foreign patents are pending.

Checker, CheckMate, Cognex, and the Cognex logo are trademarks, or registered 
trademarks, of Cognex Corporation. Microsoft, Windows, and the Windows logo are 
trademarks, or registered trademarks of Microsoft Corporation in the United States and/or 
other countries.

590-6590 Revision 1.3

Region

Telephone

Direct E-Mail

North 
America

+1-508-650-6300

[email protected]

Japan

+81-3-5977-5400

[email protected]

Europe

+33 1 47771550

[email protected]

Cable (power and I/O)

24AWG, 12’, pigtail

24V power fuse

Output fuse

500 milliamp, 60V rated resettable fuse that will 
recover after an overload is removed. Protects 
against over voltage and reverse wiring.
200 milliamp, 30v rated resettable fuse that will 
recover after an overload is removed. Protects 
each output from over current.

Weight

8.47 oz (240 g)

Operating temperature
Storage temperature
Operating humidity
Protection
Maximum altitude
Shock
Vibration

32° to 122°F (0° to 50°C)
-22° to 176°F (-30° to 80°C)
0% - 90% non-condensing
IP67
2000 meters
80Gs for 5ms on each axis (per IEC 68-2-2)

10Gs (10-500Hz) at 100 M/sec

2

 / 15mm for 2 

hours in each axis (per IEC 68-2-6)

 

7

48

6

25

3

1

9

13

6

24

8

57

1

2

91

0

1

3

1

1

14

18

15

16

17

21

19

20

22

Use this ruler to meas

ur

e the field of view

Place the ruler the same distance fr

om

 Checker as your par

t will be.

Inc

h

es

mm