Set up Outputs, Test, and Run

Checker has two user-configurable output lines: 

Output 0

 and 

Output 1

. You can configure 

Checker to send a signal on either line when a part is detected, passed, or failed, or you can 
disable the output line.

Test your job at production speed to make sure that good parts pass and bad parts fail. After 
testing, adjust the timing of the job’s output signals as required. Before disconnecting the PC from 
Checker, make sure to save your job to Checker and to the PC. 

To put Checker to work, enter Run mode, disconnect the USB cable, and replace the rubber plug 
over the USB connector.

Connecting Checker

Power

Part Detect Signal Input 

Output 0 and Output 1

4

+

+ Red

 Black

24 VDC

Voltage: 

+24 VDC (22-26 VDC)

Current:

 150 mA max

+

 White w/orange stripe

Solid orange

24 VDC

Trigger ON

: +24 VDC (5 mA)

Trigger OFF

: < 2 VDC (<1.5 mA)

Protection: 

Opto-isolated, 

 White w/orange stripe

Solid orange

Output

DC common

+VDC

Photoelectric sensor

+

24 VDC

Example: Connecting a Photoelectric sensor as an External Trigger

polarity-independent

Output 0

: Blue & White w/Blue Stripe

Output 1

: Gray & White w/Gray Stripe

Output

: Solid-state switch rated at 

Max off leakage current

: 200 µA

Protection: 

Opto-isolated. Protected 

+

+ White w/color stripe

– Solid color

24 VDC

Load

100 mA max

Max voltage drop

: 3.5 VDC @ 100 mA

 resistive 

load

Example: Connecting to a PLC

White w/blue  

Gray – 

White w/gray 

Blue – 

+

24 VDC

Common

PLC

Input 0

Input 1

Input 7

 

from short circuit, overcurrent, 
and reverse polarity.

+

+ White w/color stripe

– Solid color

24 VDC

Load

100 mA max

Method 2:

Method 1:

100 mA and 24 VDC max