COFFEtek
LTD
47
23/02/17
Issue 1
VITRO X3
CONNECTING THE WATER SERVICES
Refer to the current requirements of The Model Water Bylaws 1986
Statutory Instrument (SI) No.1147.
8.
The water supply should be taken from a 15mm rising main at a pressure of between
0.08MPa to 1MPa and should be fitted with a stopcock to isolate the supply during
servicing. A 15mm double backcheck valve, with inspection port, should be fitted to the
flexible hose.
9.
A mains water blocker MUST be fitted in the mains water supply line before the water
reaches the vending machine.
10.
The outlet should be fitted with BSP connections and must be positioned within 1.5m of the
machine to ensure correct fitting of the hose. If possible, the outlet should be located behind
the machine to prevent misuse.
11.
Before connecting the machine hose to the mains outlet, flush the system, via the stopcock,
to remove any impurities that may have accumulated in the mains supply pipe.
12.
Connect the machine hose to the mains outlet using the seals supplied and ensure that all
fittings are tight. Turn on the water supply at the stopcock and check for leaks, both behind
and inside the machine.
IF THE EQUIPMENT WAS SUPPLIED WITH A MAINS WATER HOSE, THIS HOSE SHOULD
BE USED. DO NOT USE A HOSE FROM A PREVIOUSLY INSTALLED PRODUCT EVEN IF IT
WOULD FIT. TO DO SO COULD LEAD TO A HEALTH HAZZARD.
Summary of Contents for VITRO X3
Page 1: ...VITRO X3 BEVERAGE MACHINE TECHNICAL MANUAL ...
Page 5: ...COFFEtek LTD 5 23 02 17 Issue 1 VITRO X3 This page is intentionally blank ...
Page 61: ...COFFEtek LTD 61 23 02 17 Issue 1 VITRO X3 Section 4 Exploded Parts Diagram ...
Page 62: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 62 ...
Page 63: ...COFFEtek LTD 63 23 02 17 Issue 1 VITRO X3 ...
Page 64: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 64 ...
Page 65: ...COFFEtek LTD 65 23 02 17 Issue 1 VITRO X3 ...
Page 66: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 66 ...
Page 69: ......