COFFE
tek
LTD
VITRO X3
Issue 1
23/02/17
12
Tank Filling & Overflow Protection
23.
The control system will only open the inlet valve for a maximum of 40 seconds. If the tank
is not full at the end of this time the machine will enter a fault condition. The internal display
will read “TANK FILL FAULT CALL OPERATOR” for the Instant system or “GROUP
WATER SYSTEM FAUT” for the Espresso. This fault can be cleared by switching the
machine off and on and attempting a refill.
Note: An empty tank may take several cycles to fill completely depending on water pressure.
24.
The second protective mechanism is designed to act as a fail-safe in the event that a slow
leak occurs which does not result in the liquid entering the drip tray. The machine will
cease all attempts to fill the tank after 20 tank top ups have been made, if no selections
have been taken in the meantime.
FIG 1.2 WATER SYSTEM
– FUNCTIONAL DIAGRAM
Inlet Valve
Overtemp
Cutout 1
Overflow
Valves
A
TEA
BREWER
A
Instant
Boiler
B
C
Mixer
HOT WATER
Header
Tank
Espresso
Boiler
C
ESPRESSO
BREWER
GROUP
Overtemp
Cutout 2
Valves
Summary of Contents for VITRO X3
Page 1: ...VITRO X3 BEVERAGE MACHINE TECHNICAL MANUAL ...
Page 5: ...COFFEtek LTD 5 23 02 17 Issue 1 VITRO X3 This page is intentionally blank ...
Page 61: ...COFFEtek LTD 61 23 02 17 Issue 1 VITRO X3 Section 4 Exploded Parts Diagram ...
Page 62: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 62 ...
Page 63: ...COFFEtek LTD 63 23 02 17 Issue 1 VITRO X3 ...
Page 64: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 64 ...
Page 65: ...COFFEtek LTD 65 23 02 17 Issue 1 VITRO X3 ...
Page 66: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 66 ...
Page 69: ......