17.
13. Error messages – SERVICE
Tea Cater
Error messages E1, E2, E3 and E4 are shown in the display.
NB The machine must be unplugged from the mains during all installation work.
LEVEL CHECK
TEMPERATURE CHECK
E1
shown in display =
Level sensor short electrode is Clean level sensor.
earthed, but not the long one.
Replace.
Cables incorrectly
connected.
E4
shown in display =
Filling is slow.
Restart machine.
Poor water pressure.
Water tap not open.
E2
shown in display =
Temperature outside specified range 5
°C
- 105
°C.
Temp. sensor failure.
Replace.
Wire loose.
E3
shown in the display =
Heating time too long.
Restart machine.
Solid state defect.
Replace.
Element defect.
Replace.
Overheating protection
tripped or defective.
NB All installation and repair work must be carried out by a
qualified electrician.