background image

5.1. Operating voltage and frequency

The fixture may operate at voltages ranging from 90 to 250V AC at a frequency of 50 or 60 Hz. 

It is not necessary to effect any setup procedures, Strip Lite Led RGB

will automatically adjust its operation to suit any 

frequency or voltage within this range. 

5.2. Mains connection

Mains cable characteristics

The mains cable provided is thermally resistant, complying to the most recent international standards. It meets or exceeds VDE and IEC
norms, IEC 331,IEC 332 3C,CEI 20 35.
NB: In case of cable replacement, similar cable with comparable thermal resistant qualities must be used exclusively (cable 3x1.5 ø external
10 mm, rated 300/500V, tested to 2KV, operating temperature -40° +180°, 

Coemar

cod. CV5309).

Connection to mains power
Strip Lite Led RGB 

is equipped with two power connectors, one as input and one as output, which can be used to connect more fix-

tures in series. 
The maximum current absorbed from 

Strip Lite Led RGB

is indicated in the chart below:

•230/240V 

0,5  amps constant current in normal operation.

•100/115V 

1,1  amps constant current in normal operation.

The maximum working current of the connectors is 

16A

.

The maximum absorption Imax is given from the sum of the absorptions of all the 

Strip Lite Led RGB

connected in series.

Example:
For a series of 5 

Strip Lite Led RGB

connected at 100V,

Imax = 5 x 1,1 = 5,5A

In the following figure you can see an example of series connection:

ATTENTION!!

• The use of a thermal/magnetic circuit breaker is recommended. Strict adherence to regulatory norms is strongly

recommended.

• Strip Lite Led RGB should not be powered through a Dimmer as this may damage the internal switching powersupply.
• Prior to connecting the device to mains power, ensure that the mains characteristics are within the recommended

range for use with the Strip Lite Led RGB.

• A good earth connection is essential for the correcdt operation of the Strip Lite Led RGB. Never install the unit unless

the yellow/gree earth cable is securely connected.

• All cabling and connections should be carried out by suitably qualified personnel.

Imax=16A

ground

neutral

live

brown

blue

yellow/green

main

ATTENTION!!

The absorption of the series of Strip Lite Led RGB (Imax) can never be more than 16A.

5. Powering up

11

English

Summary of Contents for Strip lite

Page 1: ...manuale di istruzioni instructions manual Version 1 0 strip lite LED RGB ...

Page 2: ...ided above the relative service information of the model and the retailer from whom you purchased your Strip Lite Led RGB this information will assist us in providing spare parts repairs or in answering any technical enquiries with the utmost speed and accuracy ATTENZIONE la sicurezza dell apparecchio è garantita solo con l uso appropriato delle presenti istruzioni per tanto è necessario conservar...

Page 3: ... frequency 35 5 2 Mains connection 35 6 DMX signal functions Pag 36 6 1 Connecting DMX signal 36 6 2 Powering up 36 6 3 DMX addressing 37 6 4 DMX functions 6 channels 37 6 4 DMX functions 10 channels 38 7 Test function Pag 38 8 Light ON function Pag 39 9 Compact 6 Ch function Pag 39 10 Auto function Pag 40 10 1 Master Slave mode 40 10 2 Stand Alone mode 41 11 DR1 function Pag 42 11 1 Functions usi...

Page 4: ...nology inherent in the Strip Lite Led RGB requires the use of specialised personnel for all service applications refer all work to your authorised Coemar service centre 4 A good earth connection is essential for proper functioning of the projector Never operate the unit without proper earth connection 5 The mains cable should not come into contact with other cabling 6 Never handle the unit with we...

Page 5: ... Maximum ambient temperature 35 C 95 F Weight 7 7 Kg 16 9 lbs 8 5 Kg 18 7 lbs IP Rating IP20 3 2 Strip Lite Led 1mt dimensions 118mm 4 64 152mm 6 1009mm 39 72 95mm 3 75 42mm 1 65 757mm 29 8 200mm 7 87 Versione Standard Standard version Versione con supporto optional cod 8052 Version with optional support cod 8052 207mm 8 17 983mm 38 71 220mm 8 66 1027mm 40 44 100mm 3 94 3 Product specifications 5 ...

Page 6: ...cription 1 Side panel 2 Led control PCB 3 PCB group 4 Lens group 5 Front frame 6 Switching power supply 968mm 38 11 100mm 3 94 1194mm 47 02 220mm 8 66 200mm 7 87 Versione Standard Standard version Versione con supporto optional cod 8052 Version with optional support cod 8052 95mm 3 75 42mm 1 65 118mm 4 64 152mm 6 1220mm 4 ft 207mm 8 17 1238mm 48 75 English ...

Page 7: ...ppropriate clamps B affixed to the fixture in the holes A provided as shown in the following diagram Floor mounted installations If the fixture is floor mounted we recommend the use of appropriate clamps C optional cod 8052 as shown in the following diagram ATTENTION Always ensure that your support structure and fixings bolts clamps etc are rated to support the weight of the fixture 757mm 29 8 A B...

Page 8: ...h suitably rated for the purpose 4 3 Adjusting beam direction If the Strip Lite Led RGB is floor mounted it can be tilted to adjust the beam output To perform this adjustment follow the instruc tions set out below 1 Loosen the handles E located on the side of the projector thus allowing the inclination to be changed 2 Adjust the projector s tilt 3 Refasten the handles E on the side of the projecto...

Page 9: ...t suitable for different lighting applications The standard optical group fitted on Strip Lite Led RGB is composed by a group of lenses that gives 12 beam angle Here following you will find instructions to install different optical groups 1 Remove the screws F 1 Remove the front frame G and the plexiglass H 3 Remove the screws L 9 English ...

Page 10: ... 6 Insert the plexiglass H and the front frame G as per their original positions 7 Tighten the F fixing screws The following table details the range of beam angle available for the Strip Lite Led RGB Strip Lite Led type Optical group Beam angle RGB 1mt Narrow lenses standard cod 8053 13 12 RGB 1mt Medium lenses cod 8053 21 23 RGB 1mt Wide lenses cod 8053 5 35 RGB 4ft Narrow lenses standard cod 805...

Page 11: ... normal operation 100 115V 1 1 amps constant current in normal operation The maximum working current of the connectors is 16A The maximum absorption Imax is given from the sum of the absorptions of all the Strip Lite Led RGB connected in series Example For a series of 5 Strip Lite Led RGB connected at 100V Imax 5 x 1 1 5 5A In the following figure you can see an example of series connection ATTENT...

Page 12: ...low pin 1 GND pin 2 data pin 3 data Should your DMX 512 controller output signal via a cannon XLR5 5 pin pins 4 and 5 should remain unconnected 6 2 Powering up After having followed the preceding steps turn on mains power on to the unit The POWER led located near the dip switch panel will come on Turning on power with DMX signal connected The yellow DMX led will flash to indicate that DMX 512 is b...

Page 13: ...roportionalcontrolofthepercentageofgreencolourfrom0to100 0 255 0 100 4 blue proportional proportionalcontrolofthepercentageofbluecolourfrom0to100 0 255 0 100 5 no function step spare channel allows the compatibility with RGB W version 0 255 0 100 step noeffect 0 9 0 4 proportional variable speed strobing effect from slow to fast 10 57 4 22 step stopstrobe 58 59 23 23 proportional sequencedpulseeff...

Page 14: ...ional proportionalcontrolofthepercentageofredcolourfrom0to100 0 255 0 100 7 green proportional proportionalcontrolofthepercentageofgreencolourfrom0to100 0 255 0 100 8 blue proportional proportionalcontrolofthepercentageofbluecolourfrom0to100 0 255 0 100 9 no function step spare channel allows the compatibility with RGB W version 0 255 0 100 step noeffect 0 9 0 4 proportional variable speed strobin...

Page 15: ...ompact 6 ch function ATTENTION Setting the Light ON dip switch to active inhibits control via DMX signal The three colour dip switches set to the OFF position turn off the colour LIGHT ON dip switch set to ON RED off GREEN off BLUE at 100 dip switches 16 32 set to ON ON 256 auto test light on DR1 1 2 4 8 16 32 64 128 LIGHT ON dip switch set to ON RED at 30 dip switch 1 set to ON GREEN at 100 dip s...

Page 16: ...f setting the Auto dip switch to the ON position and selecting a program for it to follow by making a selection from the following dip switches 1 2 4 8 256 There are 4 programs which can be select ed dip switches 1 2 4 8 select programs 1 2 3 and 4 respectively dip switch 256 runs all four programs sequentially To configure a Strip Lite Led RGB as SLAVE is simply a matter of setting the Auto dip s...

Page 17: ... the Strip Lite Led RGB as STAND ALONE simply set dip switch Auto to the ON position and select the program you wish to run and the hold and crossfade times to follow as described in the previous section Strip Lite Led RGB set as STAND ALONE running program 1 ON 256 auto test light on DR1 1 2 4 8 16 32 64 128 ATTENTION When the AUTO function is selected DMX signal reception is disabled to avoid sy...

Page 18: ... be installed into the DMX signal chain between the fixture and the controller following the instructions located internally on the unit The DR1 dip switch must be set to the ON position from this point on dip switches 1 to 128 take on the task of assigning an iden tifying value ID to the fixture They no longer set the fixture s DMX address which is done by the DR1 The maximum number of unique IDs...

Page 19: ...d the scene of the unit If DMX signal is not applied the recorder setting will appear at the end of reset operation when the unit is switched on enter o o es 0 1 2 7 enter enter o es 0 1 2 7 enter enter o es 0 1 2 7 enter enter o 0020 0020 0020 RED2 Test red 2 GRE2 Test green 2 BLU2 Test blue 2 COMPchannel compression To set the number of used DMX channels o o enter enter enter 10CH 10 channels 6C...

Page 20: ...erform a reset and the display will show for a few seconds After this the display will show ALIG confirming that you have entered electronic calibration mode ATTENTION The alignment procedure can only be carried out when DMX 512 signal is connected ATTENTION This procedure should only be undertaken by qualified and experienced technical personnel menu F U NC MEAS AOO1 MODE o o 10 DMX value reading...

Page 21: ...reen led 1 maximum intensity enter 0250 enter o 0252 MA B1 blue led 1 alignment Alignment blue led 1 maximum intensity enter 0250 enter o 0248 o es es es es es es o o o o o enter o enter 0001 enter o 0010 enter 0001 enter o 0012 enter 0001 enter o 0015 enter 0250 enter o 0255 enter 0250 enter o 0252 enter 0250 enter o 0248 es es es es es es o o o o o UPLDUpload Software upload from DR1 o 0000 Uplo...

Page 22: ...ce Led Function Led on Led off Led flashing Green Power Present Absent Undefined Yellow DMX state DMX poorly connected No DMX signal DMX OK 12 Switch panel signal MESSAGE CODE DESCRIPTION DTER DATA Error The initial configuration settings are fautly or have been loaded incorrectly The projector has loaded its default configuration Turn the projector off and on again and if the error persists the E...

Page 23: ...at the green Led is on if so check the incoming voltage to the Strip Lite Led RGB Check the main pcb fuse and that of the switching powersupply Strip Lite Led RGB doesn t respond to DMX signal Incoming DMX may not be being received by the Strip Lite Led RGB check that the led indicating DMX input is flashing If not check the DMX console s output and any cabling for continuity Check the dip switch ...

Page 24: ...2 A 46042 Castel Goffredo Mantova Italy ph 39 0376 77521 fax 39 0376 780657 info coemar com Coemar si riserva il diritto di apportare modifiche senza preavviso Coemar reserves the right to effect modifications without notification ...