background image

English 

 

 
Thank you for  having purchased a Coemar product. You  have  assured  yourself of  a  fixture of the highest quality, both in the 
componentry and in the technology used. We renew our invitation to you to complete the service information form on the previous 
page. This will assist in providing prompt and accurate advice from your Coemar service centre, which you can thoroughly trust and 
to which you can submit any requests for service or information. Following the instructions and procedures outlined in this manual 
will ensure the maximum efficiency of this product for years to come. 

1.Packaging and transportation 

1.1  Packaging 

Open the packaging and make sure that no part of the equipment has suffered any damage during the transportation. In case of 
damage to the fixture, contact your currier and your supplier immediately by telephone, fax or email, and inform them you will  
formally notify them in writing through registered letter. 

Packing List 

Make sure the packaging contains: 

Reflection LEDko P

 

2 This instruction manual. 
3-main power plugs 

1.2 Trasportation 
Reflection LEDko P

 must be transported exclusively in its original packaging or in an appropriate flight case. 

2. General information 

2.1 Important safety information. 
Fire prevention: 

 

1.

Never locate the fixture on any flammable surface. 

2.

Minimum distance from flammable materials: 0,5m. 

3.

Minimum distance from the closet illuminable surface: 0,5m. 

4.

 Connect the projector to mains power protected by a thermal magnetic circuit breaker.

 

Preventing from electric shock. 
1.

 Presence of high voltage inside of the fixture. Insulate the projector from mains supply before opening or performing any function 

which involves touching the inside of the fixture, including lamp replacement.. 

2.

 For the connection to the mains, adhere strictly to the guidelines outlined in this manual. 

3.

 The level of technology of 

Reflection LEDko P 

requires the use of specialised personnel for all service applications; refer all 

work to your authorised 

Coemar 

service centre. 

4.

 A good earth connection is essential for the proper functioning of the projector. Never connect the fixture if there is no earth 

connection. 

5.

Mains cables must not come into contact with other cables. 

6.

Do not operate the projector with wet hands or in an area where water is present. 

7.

The fixture must never be located in an exposed position, or in areas of extreme humidity. 

Safety.

 

1.

 The projector must always be installed with bolts, clamps, or other fixing devices which are suitably rated to support the weight of 

the projector. 

2.

 Always use a secondary safety fixing device with chain or steel wire of a suitable rating to sustain the weight of the unit in case of  

failure of the principal fixing point. 

3.

 The external surfaces of the unit, at various points, may reach 60°C. Never handle the unit until at least 10 minutes have elapsed 

since the lamp was turned off 

4.

 Never install the fixture in an enclosed area lacking sufficient air flow; the room temperature must not exceed 35°C. 

5. 

The projector contains electronic and electrical components which must under no circumstances be in contact with water, oil or 

any other liquid. Failure to do so will compromise the proper functioning of the projector. 
 

2.2 Warranty conditions 

 
1. The fixture is guaranteed for a period of 12 months from the date of purchase against manufacturing or materials defects. 
2. The warranty does not extend to damage caused by inappropriate usage, use by inexperienced operators or inadequate 
maintenance. 
3. The warranty is immediately void if the projector has been tampered or opened by unauthorized personnel. 
4. The warranty does not extend to fixture replacement. 
5. Both the serial number and the model  of the projector are required for any advice or service from your authorised service centre. 
 

2.3 EC Norms 
 

The projector meets all fundamental applicable EC requirements. 

 

Summary of Contents for Reflection LedkoP

Page 1: ...Instruction manual Manuale di istruzioni Ver 1 0 DIS151 ...

Page 2: ...ring any technical enquiries with the utmost speed and accuracy Prendete nota nello spazio apposite dei dati relative al modello e al rivenditore del vostro Reflection LEDko P questi dati ci permetteranno di assistervi con la massima rapidità e precisione WARNING the security of the fixture is granted only if these instructions are strictly followed therefore it is absolutely necessary to keep thi...

Page 3: ...owering up 11 5 1 Operating voltage and frequency 11 5 2 Connection to mains power 11 6 Control signal connections 12 6 1 Control signal connection by XLR5 plugs 12 7 Turning on the projector 12 7 1 DMX address of the unit 12 7 2 DMX functions 13 8 Display panel functions 14 8 1 Quick guide to menu 14 8 2 Rapid count 14 8 3 Main function menu FUNC 15 8 4 Measures and test s MEAS 16 8 5 User settin...

Page 4: ...manual 3 The level of technology of Reflection LEDko P requires the use of specialised personnel for all service applications refer all work to your authorised Coemar service centre 4 A good earth connection is essential for the proper functioning of the projector Never connect the fixture if there is no earth connection 5 Mains cables must not come into contact with other cables 6 Do not operate ...

Page 5: ...characteristics Power 90 250 Vac 50 60Hz Autosensing Maximum current 0 67A 230 Vac 1 76 A 90VAC Power factor Cos ϕ 0 9 Light source wattage 140 W Maximum room temperature 35 C 95 F Weight 5 Kg 11 2 lbs main body Grado di protezione IP20 3 2 Dimensions ...

Page 6: ...Yoke locking handle Interchangeable optic Profiler blade Gel frame locking spring Lens adjusting handles Multifunction LCD display MENU Key to access to menu or get back to previous page ENTER Key to confirm choices o access to submenues Key to scroll menu pages and increment values Key to scroll menu pages and decrease values Main power input Main power output to power further units DMX 512 signa...

Page 7: ...o free the cap itself set the optic s flange tilted about 60 Insert the optic s flange into the body s receptacle and turn the optic 60 until it is firmly assembled to the projector body free to rotate but not free to detach itself from the body Ensure the optic to the body by tightening the two screws previously loosened ...

Page 8: ... 4 3 Safety chain When hanging Reflection LEDko P it is recommended to use a safety chain as required by current legislation The safety chain must pass through the handles of the unit and then attached to the structure If using steel cables and chains not Coemar s production make sure they are suitable to support the weight of the unit according to normative UL ETL required the weight of 6 complet...

Page 9: ...ich can be used to connect more fixtures in series no more than 16 units 230V or 8 units 115V The max absorption of Reflection LEDko P is reported in the following table 230 240V 0 67 A constant during normal exercise 90V 1 76 A constant during normal exercise WARNING Never link more than 16 units at 230 V or 8 units at 90 V In the following figure you can see an example of series connection WARNI...

Page 10: ...signal has not been received Check the connection cable and the mixer functioning 7 1 DMX address of the unit Each projector can use up to 5 address channels for its complete operation and is controlled by a DMX 512 signal for further information see section 7 2 DMX functions DMX addressing When powered up initially each projector will show A001 which indicates DMX address 001 for example A second...

Page 11: ... control frequency tuning 2000Hz LED control frequency tuning 2500Hz LED control frequency tuning 3000Hz LED control frequency tuning 3500Hz LED control frequency tuning 4000Hz stop strobe random strobe effect with variable speed from slow to fast non syncronised colors 5 special functions step 600 Hz park no effect LCD display off LCD display on LED control frequency tuning 1000Hz 4 strobe no eff...

Page 12: ...selection 8 1 Quick guide to menu In order to access the functions just press the menu button press the key or to scroll pages To select the desired function press enter key 8 2 Rapid count By the display panel of Reflection LEDko P It is possible to quickly change the various numbers displayed for the different functions in the following 3 manners 1 Pressing the or buttons will cause the count to...

Page 13: ...r 5 to unlock RVRS HOLD AA VV ON OFF Store DIMMER STROBE 0 255 0 255 D MAX RESE DFSE Disables the adjusting of the leds setting them at maximum output It permits the reset of the unit Keeping pressed ENTER and MENU at the turning on of the unit It allows to access ALIG features It restores all the settings at default value excepting of led settings and hour meter ON OFF enter SURE LED AUTO allows ...

Page 14: ... value called RATE frequency of signal updating in milliseconds It shows the error message of the alarm in progress It shows the luminous efficiency of the LEDs M1234 It shows the led s life values in hours LIF R led module life resettable LIFE life of total modules installed on the unit since now not resettable UNIT life of the projector It shows the led s emission frequency It may be useful if f...

Page 15: ...h its own unique identity number ID WARNING If you set as identification number 0 Reflection LEDko P will not be recognized by DR1 and DR1 Plus Never assign the same ID to two or more units of a same DMX line This causes the failure of the system DR1 and DR1 Plus will display an error message For more information see the manual for DR1 or DR1 Plus 8 7 Electronic alignment of the leds The display p...

Page 16: ...mode is only achievable by connecting the DMX signal by keeping pressed MENU and ENTER keys during reset for 10 seconds MIN channel 1 MAX channel 1 MIN channel 2 MAX channel 2 MIN channel 3 MAX channel 3 MAX channel 4 MIN channel 4 LEDs of channel 1 alignment at minimum intensity LEDs of channel 1 alignment at maximum intensity LEDs of channel 2 alignment at minimum intensity LEDs of channel 2 ali...

Page 17: ... function properly Check the DMX address indicated on the display and the number of channels generated by the mixer control We recall in this connection that some controllers do not generate all the 512 channels 10 Accessories and spare parts Reflection LEDko P is a very versatile fixture optional accessories for its customization are available under request Coemar order code Description AFO9305 F...

Page 18: ...unding and correct attachment of all extractable connectors Press the connectors if necessary and reposition as before 11 3 Fuses Reflection LEDko P has an automatic fuse that in most cases does not need to be replaced 12 F A Q and answers The following list shows common issues that may be simply solved If issues persist the unit must be repaired by qualified personnel or just contact your Coemar ...

Page 19: ...ppliers have been checked and are produced in compliance with the Directive in question Reference Title 2004 108 EC Directive of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC EMC 2006 95 EC Directive of the European Parliament and the Council of 12 Dec...

Page 20: ...2 A 46042 Castel Goffredo Mantova Italy ph 39 0376 77521 fax 39 0376 780657 info coemar com Coemar si riserva il diritto di apportare modifiche senza preavviso Coemar reserves the right to effect modifications without notification ...