Via the
XLR5
DMX IN
socket, the
DR1
receives
DMX 512 signal
which conforms to the international standard for digital
DMX
512signal, regulated by the
USITT (U.S Institute of Theatre Technology).
Connection between the
DMX 512
controller and the
DR1
follows the standard:
Pin 1= Ground (GND)
Pin 2= DATA -
Pin 3= DATA +
Pin 4= Optional - (not connected)
Pin 5= Op (not connected)
Should you have the need to order components for signal connection, the following are the relevant coemar order codes:
ME 4965
(XLR 5 plug)
ME 4966
(XLR 5 socket)
CV 4158
(per metre 2 core screened Ø 0,5 cable)
Connection should be via 2 core screened cable, according to the standard for signal transmission.
The screening should be connected to pin number 1 of the XLR connector and should be isolated from the
metal casing of the connector having regard to polarity.
Connection between the
DR1
and any other device should always be made to the international standard:
Connect the
DR1
to your
DMX
universe as shown in the following figure:
All the compatible projectors whose displays you wish to manipulate should be connected via the OUT socket of the
DR1
.
You may address up to 250 projectors via the
DR1
Should your installation be utilising a dmx splitter, ensure that device has been designed for bi-directional communication and that
it supports the
DMX 512/A.
standard.
Coemar
recommends the use of a BID.O.S., a powerful bi-directional Opto-isolator.
BID.O.S 6 rack
(cod. 660)
BID.O.S 6 truss
(cod. 661)
Attention
The system will not function if a mono-directional device is installed between the projectors and the
DR1
.
Ad altri
dispositivi DMX 512
Connect to other
DMX 512 devices
IN
OUT
IN
OUT
Controller
DMX 512
OUT
3
2
1
4 n.c.
5 n.c.
5 pin XLR 5/M
5 pin XLR 5/F
4. DMX 512 signal connection
23