11. Error messages
DIGIfactor
club
6x2,5Kw
assists the installer and user in determining the reasons for possible failures; its memory contains the
following error messages.
In the majority of cases, it may be advisable to seek the advice of an individual who has experience with the causes of errors
which are described below
EEPROM access/reading error.
DIGIfactor
club
6x2,5Kw
will operate only at the factory presets, ot
any changes made via the menu functions. This indicates that the EEPROM is defective or missing.
Attention!
: default settings may be incompatible with any switching circuits connected; if this
occurs, ensure all functions are returned to your settings. Contact your
coemar
service centre
function display
An error has occured in the EEPROM data. This error message will be shown immediately after powe-
ring up the unit. . In this situation
DIGIfactor
club
6x2,5Kw
will attempt to rectify the error itself;
success will depend upon the seriousness of the error.
DIGIfactor
club
6x2,5Kw
will reset itself
after the error has been corrected although it should be noted that data enterd via the menu func-
tions may have been lost.
Attention!
: default settings may be incompatible with any switching cir-
cuits connected; if this condition is encountered, ensure all functions are returned to your settings.
function display
The temperature is measured at below 15°C and is below the capacity of the unit to measure.
This error will not compromise the correct functioning of the dimmer, however, it may indicate that
the thermal sensor may have shifted its position in the dimmer’s internals, perhaps during transporta-
tion. A check of this is recommended.
function display
The number of channels being transmitted to the
DIGIfactor
club
6x2,5Kw
are below those indi-
cated by its DMX address.
The DMX signal cannot be interpreted correctly as it is incomplete.
The dimmer requires more channels of DMX to be sent; consult your controller’s manual
function display
No DMX signal present or not standard DMX 512.
Check all DMX connections and the DMX 512 controller which may be switched off
function display
The frequency, as measured during a electronic menu function falls below the range of the unit’s
measurement capacity, which is between 10 and 99 Hz
This condition can only be detected by a electronic menu function. The problem will need to be recti-
fied in the short term.
function display
The frequency, as measured during a electronic menu function exceeds the range of the unit’s measu-
rement capacity, which is between 10 and 99 Hz
This condition can only be detected by a electronic menu function. The problem will need to be recti-
fied in the short term.
function display
The frequency measured at start up falls between 52 and 58 Hz, and is therefore not standard.
DIGIfactor
club
6x2,5Kw
auto sets to 50 Hz; the power supply frequency problem will need to be
investigated and the problem rectified in the short term.
function display
The frequency measured at start up is below 48 Hz
DIGIfactor
club
6x2,5Kw
auto sets to 50 Hz; the power supply frequency problem will need to be
investigated and the problem rectified in the short term.
function display
The frequency measured at start up exceeds 62 Hz
DIGIfactor
club
6x2,5Kw
auto sets to 60 Hz; the power supply frequency problem will need to be
investigated and the problem rectified in the short term.
function display
An internal hardware failure has occured which is causing the unit to be unable to determine the
operating frequency of 50-60 Hz. This message appears upon start up.
Being a hardware problem, the unit will need to be referred to an autorised
coemar
sevice centre.
function display
The internal temperature has exceeded 65°.
The display will flash to indicate an abnormal state.
DIGIfactor
club
6x2,5Kw
can continue to operate but is in danger of being damaged; adequate
ventilation must be provided to resolve this problem
function display