9. Display panel functions

Attention! 

the display panel controls the proper functioning of the dimmer and its various parameters.

Altering the 

coemar 

factory  presents can vary the functioning of the dimmer, causing it to not respond to 

DMX 512

con-

trol signal; careful and thorough reading of all the following procedures is therefore recommended prior to altering any
functions.

IMPORTANT NOTES:

these notes are valid for all the functions which follow

1.

Keeping the 

+

or i

-

buttons depressed for 8 seconds for rapid scrolling.

2.

You may abort the altering of any function by simply pressing the 

menu 

button until the display shows the DMX

address

3.

To immediately go to the maximum value, press the 

+

button whilst simultaneously pressing the 

-

button.

4.

To immediatley go to the minimum  value, press the 

-

button whilst simultaneously pressing the 

+

button.

5.

You may alter single channel settings or press the 

or 

-

buttons until the display shows 

ALL

to alter all channels simulta-

neously.

6.

Changes made via the menu buttons are confirmed and recorded when the 

enter 

button is pressed.

It is always possible to over-write any settings with new ones at any time.
The reset procedure allows all settings to be returned to factory presets,  with the exception of the DMX address.

7.

Display panel functions remain active for 10 secondis if no changes are made, after which they will return to the DMX address
display/

The display panel has three menus and main functions, which are:

9.1. Test
9.2. Electical and electronic displays
9.3. Advanced functions (installer options)

9.1. Test

9.1.1. Tests every channel

Allows the testing of every outlet of the 

DIGIfactor 

club

6x2,5Kw

, without the need for a controller

You may repeat the test on any individual channel, or, alternatively:

Select an output level from 0 to 99 (maximum output);

via the digital display. As the display value increases,

note that the output level of the load does the same.

function display

Press the 

+

or 

button

Output level set to 

00

function display

Press the 

enter 

button

ALL

to test all channels simultaneously

function display

Press the 

+

or 

buttons

For example, test channel 6 (

t 6

)

function display

Press the 

+

or 

-

buttons to select the required

channel for testing

To confirm your selection of channel 

test

, the

first channel for testing is displayed as 1 (

t 01

).

Press the 

enter 

button

Channel 

test 

menu

Press the 

button

electronics display menu

function display

Press the 

menu

button

Address 

DMX 001

Power up the 

DIGIfactor 

club

6x2,5Kw

Summary of Contents for DIGIfactor club 6x2,5Kw

Page 1: ...m you purchased your DIGIfactor club 6x2 5Kw This information will assist us in providing spare parts repairs or in answering any technical enquiries with the utmost speed and accuracy WARNING the sec...

Page 2: ...input signal levels 9 2 7 Individual channel 0 10V DC input signal levels 9 2 8 Instantaneous output voltage measurement on every channel 9 3 Advanced functions installer options 9 3 1 Lamp pre heati...

Page 3: ...ver suply protection Load protection via ceramic fuses Maximum load per channel 2 5KW Number of channels 6 CE compliance Locking load connectors Locking supply connectors Fuse blown indicator on all l...

Page 4: ...of the DIGIfactor club 6x2 5Kw there are forced cooling air intake exhaust passages These pas sages should under no circumstances be covered Installation should not be onto a flammable surface a hot...

Page 5: ...NZIONE Alta tensione all interno dell apparecchio Togliere tensione prima di rimuovere il pannello Questa apparecchiatura deve essere installata esclusivamente da persone competenti seguendo scrupolos...

Page 6: ...2 5Kw is a high technology dimmer running on mains power only qualified personal should perform installation after thorough examination of this manual and bearing in mind all local norms Remove mains...

Page 7: ...ra deve essere installata esclusivamente da persone competenti seguendo scrupolosamente il manuale d installazione fornito dalla ditta e le vigenti normative Una buona connessione di terra essenziale...

Page 8: ...n plug 6 variable voltages from 0 to 10V continuous current as per international norms for analgoue transmission Connection is particualrly simple if the fixure receiving signal follows the coemar sta...

Page 9: ...ng should alwasy be connected to pin 8 of the locking din Shown is a typical 0 10v DC connection between controller and DIGIfactor club 6x2 5Kw 8 pin locking DIN M 8 pin locking DIN M DIGIfactor club...

Page 10: ...ting frequency of the power supply and auto optimisation of the unit s operation DIGIfactor club 6x2 5Kw will also display the voltage above 250V or below 180V When the display shows A001 or any other...

Page 11: ...ress DMX 1 A dimmer so addressed will respond to channels 1 through 6 of the DMX 512 controller a second dimmer should be addressed as 7 and so on in multiples of 6 A dimmer can therefore respond to w...

Page 12: ...any time The reset procedure allows all settings to be returned to factory presets with the exception of the DMX address 7 Display panel functions remain active for 10 secondis if no changes are made...

Page 13: ...FrE measures the frequency in Hertz function display Press the enter button FrE measures the frequency in Hertz function display Press the or button To confirm your selection Press the enter button El...

Page 14: ...DMX 512 signal bringing any problems to light To confirm your selection Press the enter button SEr displays significant parameters of the DMX 512 signal function display Press the or button To confirm...

Page 15: ...y Channel number 1 function display Press the enter button To measure the incoming DMX 512 signal levels function display Press the or button until dMX is displayed To confirm your selection Press the...

Page 16: ...tton until Outv is displayed Electronic display menu function display Press the menu button DMX address Power up DIGIfactor club 6x2 5Kw DIGIfactor club 6x2 5Kw will display the inco ming 0 10v signal...

Page 17: ...s the enter button DIGIfactor club 6x2 5Kw sets the dimmer channel s to the set minimum level regardless of incoming DMX signal function display Press the or buttons until the required level is achiev...

Page 18: ...o confirm your selection Press the enter button Function menu displayed function display Simultaneously press the menu and enter but tons DIGIfactor club 6x2 5Kw turns on Power up DIGIfactor club 6x2...

Page 19: ...Press the or button until PrEH is displayed To confirm your selection Press the enter button Function menu displayed function display Simultaneously press the menu and enter but tons DIGIfactor club...

Page 20: ...lection Press the enter button For example channel number 6 function display Press the or button until the required channel is selected Channel number 1 function display Press the enter button To conf...

Page 21: ...or buttons until bCuP is displayed Function menu displayed function display Simultaneously press the menu and enter b DMX address Power up DIGIfactor club 6x2 5Kw To confirm your request to record th...

Page 22: ...this point without performing a reset press the menu button function display Press the enter button A reset of all altered functions DIGIfactor club 6x2 5Kw resets to the coemar factory presets Press...

Page 23: ...ON the following procedure will not erase the scene it will simply de activate it until future use Electronic display menu function display Press the menu button DIGIfactor club 6x2 5Kw turns on Power...

Page 24: ...Strd Lin CH01 CH02 CH03 CH04 CH05 CH06 CH07 CH08 CH09 CH10 CH11 CH12 cdiM ScH0 ScH1 cdiM ScH0 ScH1 cdiM ScH0 ScH1 cdiM ScH0 ScH1 cdiM ScH0 ScH1 cdiM ScH0 ScH1 cdiM ScH0 ScH1 cdiM ScH0 ScH1 cdiM ScH0...

Page 25: ...cH0 ScH1 cdiM ScH0 ScH1 cdiM ScH0 ScH1 cdiM ScH0 ScH1 Tabella riepilogativa dei settaggi funzionali CH PrEH SEtv FUnC CUrv rECL BCUP Prot rCL1 rCL2 rCL3 rCL4 rCL5 rCL6 rCL7 rCL8 rCL9 bC 1 bC 2 bC 3 bC...

Page 26: ...hown below 4 If the switch is opern DIGIfactor club 6x2 5Kw operates normally if the switch is closed the scene previously saved as the back up will be activated There is a delay of some 10 seconds pr...

Page 27: ...te The dimmer requires more channels of DMX to be sent consult your controller s manual function display No DMX signal present or not standard DMX 512 Check all DMX connections and the DMX 512 control...

Page 28: ...The EEPROM is being re initialised This may occur if the EEPROM is new or has been erased comple tely It is being re initialised with the unit s default settings function display...

Page 29: ...ture s lamp is not blown and it is operating normally 3 Check the controller to isolate the dimmer as the cause of the problem 4 Check the channel monitor on the front panel 5 Perform the test procedu...

Page 30: ...depending upon the unit s operating conditions To effect this cleaning use a common brush vacuum cleaner or air compressor If necessary do not hesitate to perform this cleaning more frequently than r...

Page 31: ...ble as spare parts from your authorised coemar service centre To assist us in providing your with prompt and accurate service carefully specify the model and serial number of the unit and the spare pa...