Coemar Concept Design 384 Manual Download Page 4

4

Congratulations on having purchased a 

Coemar

 product. You have assured yourself of a fixture of the highest 

quality, both in componentry and in the technology used. We renew our invitation to you to complete the service 

information on the previous page, to expedite any request for service information or spares (in case of problems 

encountered either during, or subsequent to, installation). This information will assist in providing prompt and ac-

curate advice from your 

Coemar

 service centre. Following the instructions and procedures outlined in this manual 

will ensure the maximum efficiency of this product for years to come.

1. 

Packaging and transportation

1.1

 

Packaging

Open the packaging and make sure that no part of the equipment has suffered any damage during the transpor-

tation. In case of damage to the fixture, contact your currier and your supplier immediately by telephone, fax or 

e-mail, and inform them you will formally notify them in writing through registered letter.

Packing list

Ensure the packaging contains:

1 Concept Design 384

1 Instruction manual 

1 Main power plugs

2

General information

2.1

 

Safety informations

Fire prevention:

1. 

Never locate the fixture on any flammable surface.

2. 

Minimum distance from flammable materials: 0,5 m.

3. 

Minimum distance from the closet illuminable surface: 0,5 m.

4. 

Replace any blown or damaged fuse only with those of identical values. Refer to the sche-

matic diagram if there is any doubt.

5. 

Connect the projector to mains power protected by a thermal magnetic circuit breaker.

Prevention from electric shock:

1. 

Presence of high voltage inside of the fixture. Insulate the projector from mains supply 

before opening or performing any function which involves touching the inside of the fix-

ture, including lamp replacement.

2. 

For the connection to the mains, adhere strictly to the guidelines outlined in this manual.

1.2

 

Transportation

The 

Concept Design 384

 should be transported in either its original packaging.

Summary of Contents for Concept Design 384

Page 1: ...Concept Design 384...

Page 2: ...providing spare parts repairs or in an swering any technical enquiries with the utmost speed and accuracy WARNING the security of the fixture is granted only if these instructions are strictly followe...

Page 3: ...9 6 3 DMX connection Pag 10 7 Turning the fixture on and DMX function Pag 11 7 1 Turning the unit on Pag 11 7 2 DMX address setting Pag 11 7 3 DMX chart 64 channels Pag 12 7 4 DMX chart 48 channels P...

Page 4: ...hone fax or e mail and inform them you will formally notify them in writing through registered letter Packing list Ensure the packaging contains 1 Concept Design 384 1 Instruction manual 1 Main power...

Page 5: ...re is under warranty for 36 months from the purchase date against factory defections 2 Damage ought to unskillfulness inappropriate use or lack of suggested maintenance are excluded from the warranty...

Page 6: ...3 A 230 V 5 A 115 V Power factor Cos 0 9 Max power consumption 500 W 350 mA Maximum internal temperature 80 C 176 F Maximum external temperature 35 C 95 F Weight without optic 3 5 kg 7 7 lbs 3 Produc...

Page 7: ...7 3 3 Back front panel description Plus button Minus button Display Menu button Enter button DMX In Out IR In RJ45 Out Power button Main In...

Page 8: ...o mains power Concept Design 384 is equipped with a power connector IEC The max absorption of Concept Design 384 is reported in the following table 230 V 3 A constant during normal exercise 115 V 5 A...

Page 9: ...to 8 outputs each output can control up to 4 channels at 350 mA constant current and a maximum of 47 Volts Up to 350mA and up to 47 V for each channel LEDs connection must be done following this sche...

Page 10: ...standards Connection is as indicated below Pin 1 GND Pin 2 data Pin 3 data Pin 4 n c Pin 5 n c Warning Ensure that all data conductors are insulated from one another the screening and the metal housi...

Page 11: ...ltiple number of the previous unit for example in 4 channels mode the second unit will have address A005 the third A009 the fourth A013 and so on Altering DMX address only available with DMX signal co...

Page 12: ...t channel from 0 to 100 0 255 0 100 16 master fine dimmer ch 2 4 proportional fine dimmer control 16 bit 0 255 0 100 Out 3 17 master dimmer ch 3 1 proportional proportional control of the percentage o...

Page 13: ...0 0 255 0 100 48 master fine dimmer ch 6 4 proportional adjust the color intensity from 0 to 100 0 255 0 100 Out 7 49 master dimmer ch 7 1 proportional proportional control of the percentage of light...

Page 14: ...nnel from 0 to 100 0 255 0 100 12 dimmer ch 2 4 proportional proportional control of the percentage of light channel from 0 to 100 0 255 0 100 Out 3 13 master dimmer out 3 proportional adjust luminous...

Page 15: ...ch 6 4 proportional proportional control of the percentage of light channel from 0 to 100 0 255 0 100 Out 7 37 master dimmer out 7 proportional adjust luminous output intensity from 0 to 100 0 255 0 1...

Page 16: ...nnel from 0 to 100 0 255 0 100 16 dimmer ch 4 4 proportional proportional control of the percentage of light channel from 0 to 100 0 255 0 100 Out 5 17 dimmer ch 5 1 proportional proportional control...

Page 17: ...3 proportional proportional control of the percentage of light channel from 0 to 100 0 255 0 100 6 dimmer ch 4 proportional proportional control of the percentage of light channel from 0 to 100 0 255...

Page 18: ...ns of the fixture so that it will respond differently to the controller therefore carefully read about the functions described here before carrying out any possible selection 8 2 Rapid count Through t...

Page 19: ...set manually some different options Dimmer it allows to set the luminous inten sity Channel 1 1 channel 1 2 etc it allows to set the color intensity individually Store stores all the new modification...

Page 20: ...Measures SUrE Sure DMX channels Allows to choose the DMX mode in which the fixture must operate Default Settings Allows to restore the factory default of the fix ture with exception of DMX address Me...

Page 21: ...the fixture occupies on the line DMX rate Shows the refresh rate of the DMX signal sent by the console Usage hours Shows the hour counter of the fixture Life shows the overall hours of the LEDs Unit s...

Page 22: ...ed the fixtures stores the signal Automatic fan standby To decrease the noise and the power consumption the cooling fan turns off after 10 minutes of fixture inactivity Error code Description nOAL No...

Page 23: ...rking of the mechanical parts and if needed replace them Make sure the fixture is not mechanically damaged If necessary replace the worn parts Electrical components Check all electrical connections in...

Page 24: ...X signal Incoming DMX signal may not being received by the unit check that the address on display does not blink check that controller and cables are in good conditions check for DMX addressing Concep...

Page 25: ...25 User notes...

Page 26: ...nter for waste electrical and electronic equipment The treatment and disposal of environmentally friendly helps prevent potential negative environ mental and health and promote the reuse and or recycl...

Page 27: ...Lighting s r l Via Carpenedolo 90 46043 Castiglione delle Stiviere Mantova Italy phone 39 0376 1514412 fax 39 0376 1514380 info coemar com Coemar reserves the right to change specifications without pr...

Reviews: