Turning the fixture on and DMX functions

7.1

 

Turning the unit on

After 

Concept Design 384

 has been connected to mains, to the controller and to the LEDs, the unit will turn 

on automatically.

The display will turn on showing the actual DMX channel (A001 default setting). If the DMX signal is not con-

nected the address will blink.

7.2

 

DMX address setting

When turned on the display will show ”A001” it indicates that the actual DMX address is 001; the unit will 

answer to channels 1 to 4, 1 to 6, 1 to 32 or 1 to 48. See DMX charts for further information about functions. 

Added units in the DMX line must have as address the multiple number of the previous unit, for example: in 4 

channels mode, the second unit will have address A005, the third A009 the fourth A013 and so on.

Altering DMX address (only available with DMX signal connected)

1. 

Press the + or – buttons until the display shows the required DMX address. The characters in the display will 

blink to indicate that the selection is not stored in memory yet.

2. 

Press the Enter button to confirm your selection. The display panel will cease to flash and the fixture will 

now respond to the new DMX 512 address.

NB:

 holding down the + or – buttons will cause the display to alter at an increate speed, allowing a faster selec-

tion to be made.

Warning!

If you alter the DMX with no DMX controller connected, the characters in the display panel will continue 

to flash even after you have pressed the ENTER button.

Summary of Contents for Concept Design 384

Page 1: ...Concept Design 384...

Page 2: ...providing spare parts repairs or in an swering any technical enquiries with the utmost speed and accuracy WARNING the security of the fixture is granted only if these instructions are strictly followe...

Page 3: ...9 6 3 DMX connection Pag 10 7 Turning the fixture on and DMX function Pag 11 7 1 Turning the unit on Pag 11 7 2 DMX address setting Pag 11 7 3 DMX chart 64 channels Pag 12 7 4 DMX chart 48 channels P...

Page 4: ...hone fax or e mail and inform them you will formally notify them in writing through registered letter Packing list Ensure the packaging contains 1 Concept Design 384 1 Instruction manual 1 Main power...

Page 5: ...re is under warranty for 36 months from the purchase date against factory defections 2 Damage ought to unskillfulness inappropriate use or lack of suggested maintenance are excluded from the warranty...

Page 6: ...3 A 230 V 5 A 115 V Power factor Cos 0 9 Max power consumption 500 W 350 mA Maximum internal temperature 80 C 176 F Maximum external temperature 35 C 95 F Weight without optic 3 5 kg 7 7 lbs 3 Produc...

Page 7: ...7 3 3 Back front panel description Plus button Minus button Display Menu button Enter button DMX In Out IR In RJ45 Out Power button Main In...

Page 8: ...o mains power Concept Design 384 is equipped with a power connector IEC The max absorption of Concept Design 384 is reported in the following table 230 V 3 A constant during normal exercise 115 V 5 A...

Page 9: ...to 8 outputs each output can control up to 4 channels at 350 mA constant current and a maximum of 47 Volts Up to 350mA and up to 47 V for each channel LEDs connection must be done following this sche...

Page 10: ...standards Connection is as indicated below Pin 1 GND Pin 2 data Pin 3 data Pin 4 n c Pin 5 n c Warning Ensure that all data conductors are insulated from one another the screening and the metal housi...

Page 11: ...ltiple number of the previous unit for example in 4 channels mode the second unit will have address A005 the third A009 the fourth A013 and so on Altering DMX address only available with DMX signal co...

Page 12: ...t channel from 0 to 100 0 255 0 100 16 master fine dimmer ch 2 4 proportional fine dimmer control 16 bit 0 255 0 100 Out 3 17 master dimmer ch 3 1 proportional proportional control of the percentage o...

Page 13: ...0 0 255 0 100 48 master fine dimmer ch 6 4 proportional adjust the color intensity from 0 to 100 0 255 0 100 Out 7 49 master dimmer ch 7 1 proportional proportional control of the percentage of light...

Page 14: ...nnel from 0 to 100 0 255 0 100 12 dimmer ch 2 4 proportional proportional control of the percentage of light channel from 0 to 100 0 255 0 100 Out 3 13 master dimmer out 3 proportional adjust luminous...

Page 15: ...ch 6 4 proportional proportional control of the percentage of light channel from 0 to 100 0 255 0 100 Out 7 37 master dimmer out 7 proportional adjust luminous output intensity from 0 to 100 0 255 0 1...

Page 16: ...nnel from 0 to 100 0 255 0 100 16 dimmer ch 4 4 proportional proportional control of the percentage of light channel from 0 to 100 0 255 0 100 Out 5 17 dimmer ch 5 1 proportional proportional control...

Page 17: ...3 proportional proportional control of the percentage of light channel from 0 to 100 0 255 0 100 6 dimmer ch 4 proportional proportional control of the percentage of light channel from 0 to 100 0 255...

Page 18: ...ns of the fixture so that it will respond differently to the controller therefore carefully read about the functions described here before carrying out any possible selection 8 2 Rapid count Through t...

Page 19: ...set manually some different options Dimmer it allows to set the luminous inten sity Channel 1 1 channel 1 2 etc it allows to set the color intensity individually Store stores all the new modification...

Page 20: ...Measures SUrE Sure DMX channels Allows to choose the DMX mode in which the fixture must operate Default Settings Allows to restore the factory default of the fix ture with exception of DMX address Me...

Page 21: ...the fixture occupies on the line DMX rate Shows the refresh rate of the DMX signal sent by the console Usage hours Shows the hour counter of the fixture Life shows the overall hours of the LEDs Unit s...

Page 22: ...ed the fixtures stores the signal Automatic fan standby To decrease the noise and the power consumption the cooling fan turns off after 10 minutes of fixture inactivity Error code Description nOAL No...

Page 23: ...rking of the mechanical parts and if needed replace them Make sure the fixture is not mechanically damaged If necessary replace the worn parts Electrical components Check all electrical connections in...

Page 24: ...X signal Incoming DMX signal may not being received by the unit check that the address on display does not blink check that controller and cables are in good conditions check for DMX addressing Concep...

Page 25: ...25 User notes...

Page 26: ...nter for waste electrical and electronic equipment The treatment and disposal of environmentally friendly helps prevent potential negative environ mental and health and promote the reuse and or recycl...

Page 27: ...Lighting s r l Via Carpenedolo 90 46043 Castiglione delle Stiviere Mantova Italy phone 39 0376 1514412 fax 39 0376 1514380 info coemar com Coemar reserves the right to change specifications without pr...