10
6.3
DMX connection
Concept Design 384
can work in DMX mode and it can be controlled by a DMX controller:
Signal connection via XLR5 connectors:
Connection is to international standards. Connection is as indicated below.
Pin 1 = GND
Pin 2 = data -
Pin 3 = data +
Pin 4 = n.c.
Pin 5 = n.c.
Warning!
Ensure that all data conductors are insulated from one another, the screening and the metal housing of
the connector.
Pin # 1 and the housing should never be connected to mains earth connection.
001
289
577
Ch.
Master
Slave
Slave
Slave
Master
Slave
Slave
Slave
DMX mode
Master/Slave - IR control model
NO DMX
NO DMX
DMX controller
Other units
Master/Slave mode
IR sensor
Other units
Other units