3. Important safety
Fire prevention
information
1. CF 1200 Spot
uses a Philips MSR 1200 SA lamp; the use of any alternative lamp
is not recommended and will null and void the fixture’s warranty.
2.
Never locate the fixture on any flammable surface
3.
Minimum distance from flammable materials: 0.5 m.
4.
Minimum distance from the closest illuminable surface: 2 m.
5.
Replace any blown or damaged fuses only with those of identical values. Refer to
the schematic diagram if there is any doubt.
6.
Connect the projector to mains power via a thermal magenetic circuit breaker.
Prevention of electric shock:
1.
High voltage is present in the internals of the unit. Isolate the projector from
mains supply prior to performing any function which involves touching the inter-
nal of the unit, including lamp replacement.
2.
For mains connection, adhere strictly to the guidelines outlined in section 7 of this
manual.
3.
The level of technology inherent in the
CF 1200 Spot
requires the use of spe-
cialised personnel for all service applications; refer all work to your authorised
coemar
service centre.
4.
A good earth connection is essential for proper functioning of the projector.
The projector should never be operated without proper earth connection.
5.
The fixture should never be located in an exposed position, or in areas of extreme
humidity. A steady supply of circulating air is essential.
Protection against ultraviolet radiation:
1.
Never turn on the lamp if any of the lenses, filters, or the carbon fibre housing is
damaged; their respective functions will only occur efficiently if they are in perfect
working order.
Never look directly into the lamp when it is operating.
Safety:
1.
The projector should always be installed with bolts, clamps, and other fixings
which are suitably rated to support the weight of the unit.
2.
Always use a secondary safety chain of a suitable rating to sustain the weight of
the unit in case of the failure of the primary fixing point.
3.
The external surface of the unit, at various points, may exceed 150°C. Never
handle the unit until at least 10 minutes after the lamp has been turned off.
4.
Always replace the lamp if any physical damage is evident.
5.
Never install the fixture in an enclosed area lacking sufficient air flow; the ambient
temperature should not exceed 35°C.
6.
The hot lamp may explode, always wait at least 10 minutes after it has been tur-
ned off prior to attempting to replace or handle the lamp.
Always wear suitable hand protection when handling the lamp.